Installation and
Operating Instructions
Vacuum Pumps
Mink MM 1104, 1144, 1102, 1142 BV
ATEX-Version, Gas Tight
Busch Produktions GmbH
Schauinslandstr. 1
79689 Maulburg
Germany
0870141675 / 190709 / Original instructions / Modifications reserved

Table of Contents

Questions and Answers

  • K
    Kathy MorrowAug 14, 2025
    What to do if my BUSCH MINK MM 1142 BV Water Pump does not start?
    • J
      Julie WarnerAug 14, 2025
      If your BUSCH Water Pump isn't starting, it could be due to several reasons. First, check the power supply to ensure the motor is receiving the correct voltage. If the power supply is adequate, the motor itself might be defective and need replacement. Another potential issue is a defective coupling (CPL), which would also require replacement.
  • L
    Laura ColemanAug 17, 2025
    Why is my BUSCH Water Pump running too hot?
    • A
      Amanda GlennAug 18, 2025
      If your BUSCH Water Pump is running too hot, several factors could be the cause. First, check for insufficient cooling by removing any dust and dirt from the machine. The ambient temperature may be too high, so ensure it's within the permitted range as specified in the Technical Data. Also, verify that the temperature of the process gases at the inlet is within the permitted limits, as detailed in the Technical Data. Finally, check the oil level and top it up if it is too low.
  • A
    Amber YangAug 21, 2025
    Why is my BUSCH MINK MM 1142 BV running very noisily?
    • M
      Meredith BlackburnAug 21, 2025
      If your BUSCH Water Pump is excessively noisy, there are a few potential causes. One possibility is a worn coupling (CPL), which would need to be replaced. Another cause could be that the oil level is too low, so you should top up the oil. It could also be due to defective bearings, in which case you should contact Busch to repair the machine.
  • K
    Katherine BondAug 25, 2025
    What to do if my BUSCH MINK MM 1142 BV Water Pump does not reach the usual pressure on the suction connection?
    • T
      Travis JohnsonAug 25, 2025
      If your BUSCH Water Pump isn't reaching the usual pressure on the suction connection, it could be due to a few reasons. The inlet screen (IS) might be partially clogged, so you should clean it. If your pump has an optional inlet filter cartridge, it may be partially clogged and need replacement. It is also possible that internal parts are worn or damaged, in which case you should contact Busch to repair the machine.
  • K
    Karen WyattAug 31, 2025
    What to do if my BUSCH Water Pump starts, but labours or runs noisily or rattles?
    • R
      Robin WhiteAug 31, 2025
      If your BUSCH Water Pump starts but runs noisily, check for loose connections in the drive motor terminal box and ensure all motor coils are properly connected, especially on motors with six coils; tighten or replace any loose connections. Also, verify that the pump is running in the correct direction. Foreign objects or stuck bearings inside the pump could also be the cause.
  • F
    fsmithSep 3, 2025
    Why is my BUSCH MINK MM 1142 BV blocked?
    • M
      Maria ScottSep 4, 2025
      Your BUSCH Water Pump could be blocked due to solid foreign matter entering the pump. Make sure the suction line is equipped with a screen and consider adding a filter. Another cause could be corrosion from remaining condensate. Check the process.
  • C
    coreygordonSep 7, 2025
    What to do if the temperature monitoring has tripped on my BUSCH MINK MM 1142 BV?
    • M
      Mark SotoSep 7, 2025
      If the temperature monitoring has tripped on your BUSCH Water Pump, indicating that the permissible temperature at the outlet has been exceeded and the pump has shut down, the problem may be insufficient air ventilation. Ensure that dust or dirt isn't impeding the cooling of the pump; clean the fan cowlings, fan wheels, ventilation grilles, and cooling fins. Also, make sure that the ambient or inlet gas temperature is not too high, and that the mains frequency or voltage are within the tolerance range. Partial clogging of filters or screens, or in the suction, discharge, or pressure line, or lines with too small diameter may also be the cause; remove any blockages or use larger diameter lines.
  • D
    David HoltSep 10, 2025
    What to do if the drive motor is running, but the BUSCH Water Pump stands still?
    • A
      Andrea WalkerSep 12, 2025
      If the drive motor is running, but the BUSCH Water Pump remains still, the coupling between the drive motor and the pump is likely defective and needs replacement.
  • T
    tylergallagherNov 26, 2025
    Why does my BUSCH MINK MM 1142 BV not reach the usual pressure?
    • B
      benjamin26Nov 27, 2025
      Your BUSCH Water Pump might not be reaching the usual pressure due to several reasons. It could be that the vacuum system or suction line isn't leak-tight; in this case, check the hose or pipe connections for leaks. If you have a vacuum relief valve/regulating system installed, it might be misadjusted or defective, requiring adjustment, repair, or replacement. A partially clogged screen in the suction connection or a filter on the suction connection could also be the cause; clean or replace them as needed. Additionally, check for partial clogging or lines with too small diameter in the suction, discharge, or pressure line, and remove any blockages or use larger diameter lines. The valve disk of the inlet non-return valve could be stuck, requiring disassembly and cleaning. If none of these ...

Summary

Product Description

ATEX Classification Explanation

Explains ATEX classification markings for inside and outside the vacuum pump.

Safety

Intended Use

Defines the purpose of the vacuum pump and requirements for its handling.

Safety Notes

Highlights potential hazards and safety measures, using DANGER, WARNING, CAUTION.

Installation and Commissioning

Installation prerequisites

Crucial checks and conditions that must be met before installing the vacuum pump.

Suction Connection

Details on connecting the suction line, including filters and material requirements.

Gas Discharge

Instructions for connecting the gas discharge line, especially for explosive atmospheres.

Electrical Connection; Controls

Guides for connecting the drive motor and control systems, including ATEX considerations.

Checking the Function of the Measurement and Safety Instrumentation

Operating Notes

Use

Reiterates intended use, ATEX requirements, and classification interpretation.

Maintenance

Maintenance Schedule

Details the intervals for monthly, 3-monthly, 6-monthly, yearly, and 5000/10000/20000 hour maintenance.

Overhaul

Troubleshooting

Spare Parts

Technical Data

BUSCH MINK MM 1142 BV Specifications

General IconGeneral
BrandBUSCH
ModelMINK MM 1142 BV
CategoryWater Pump
LanguageEnglish