Installation and
Operating Instructions
Vacuum Pumps
Mink MM 1104, 1144, 1102, 1142 BV
ATEX-Version, Gas Tight
Busch Produktions GmbH
Schauinslandstr. 1
79689 Maulburg
Germany
0870141675 / 190709 / Original instructions / Modifications reserved

Table of Contents

Questions and Answers

  • M
    melanie27Aug 14, 2025
    What to do if my BUSCH MINK MM 1144 BV Water Pump does not start?
    • M
      Matthew GardnerAug 15, 2025
      If your BUSCH Water Pump isn't starting, it could be due to several reasons. First, check the power supply to ensure the motor is receiving the correct voltage. If the power supply is adequate, the motor itself might be defective and need replacement. Another potential issue is a defective coupling (CPL), which would also require replacement.
  • J
    Jennifer DominguezAug 17, 2025
    Why is my BUSCH Water Pump running too hot?
    • S
      shelby08Aug 17, 2025
      If your BUSCH Water Pump is running too hot, several factors could be the cause. First, check for insufficient cooling by removing any dust and dirt from the machine. The ambient temperature may be too high, so ensure it's within the permitted range as specified in the Technical Data. Also, verify that the temperature of the process gases at the inlet is within the permitted limits, as detailed in the Technical Data. Finally, check the oil level and top it up if it is too low.
  • J
    Joshua JonesAug 21, 2025
    Why is my BUSCH MINK MM 1144 BV running very noisily?
    • K
      kreyesAug 21, 2025
      If your BUSCH Water Pump is excessively noisy, there are a few potential causes. One possibility is a worn coupling (CPL), which would need to be replaced. Another cause could be that the oil level is too low, so you should top up the oil. It could also be due to defective bearings, in which case you should contact Busch to repair the machine.
  • J
    johnnywellsAug 25, 2025
    What to do if my BUSCH MINK MM 1144 BV does not reach the usual pressure on the suction connection?
    • M
      Megan WiseAug 25, 2025
      If your BUSCH Water Pump isn't reaching the usual pressure on the suction connection, it could be due to a few reasons. The inlet screen (IS) might be partially clogged, so you should clean it. If your pump has an optional inlet filter cartridge, it may be partially clogged and need replacement. It is also possible that internal parts are worn or damaged, in which case you should contact Busch to repair the machine.
  • S
    Scott ReeseAug 31, 2025
    What to do if my BUSCH MINK MM 1144 BV starts, but labours or runs noisily or rattles?
    • J
      Jared GibsonAug 31, 2025
      If your BUSCH Water Pump starts but runs noisily, check for loose connections in the drive motor terminal box and ensure all motor coils are properly connected, especially on motors with six coils; tighten or replace any loose connections. Also, verify that the pump is running in the correct direction. Foreign objects or stuck bearings inside the pump could also be the cause.
  • E
    Edward GrahamSep 3, 2025
    Why is my BUSCH MINK MM 1144 BV blocked?
    • J
      joelvincentSep 3, 2025
      Your BUSCH Water Pump could be blocked due to solid foreign matter entering the pump. Make sure the suction line is equipped with a screen and consider adding a filter. Another cause could be corrosion from remaining condensate. Check the process.
  • R
    Richard CurtisSep 6, 2025
    What to do if the temperature monitoring has tripped on my BUSCH MINK MM 1144 BV Water Pump?
    • S
      Susan LesterSep 6, 2025
      If the temperature monitoring has tripped on your BUSCH Water Pump, indicating that the permissible temperature at the outlet has been exceeded and the pump has shut down, the problem may be insufficient air ventilation. Ensure that dust or dirt isn't impeding the cooling of the pump; clean the fan cowlings, fan wheels, ventilation grilles, and cooling fins. Also, make sure that the ambient or inlet gas temperature is not too high, and that the mains frequency or voltage are within the tolerance range. Partial clogging of filters or screens, or in the suction, discharge, or pressure line, or lines with too small diameter may also be the cause; remove any blockages or use larger diameter lines.
  • G
    Gavin ArmstrongSep 10, 2025
    What to do if the drive motor is running, but the BUSCH Water Pump stands still?
    • W
      Wanda FarmerSep 10, 2025
      If the drive motor is running, but the BUSCH Water Pump remains still, the coupling between the drive motor and the pump is likely defective and needs replacement.
  • M
    Misty HillNov 26, 2025
    Why does my BUSCH MINK MM 1144 BV Water Pump not reach the usual pressure?
    • A
      Amanda ValentineNov 26, 2025
      Your BUSCH Water Pump might not be reaching the usual pressure due to several reasons. It could be that the vacuum system or suction line isn't leak-tight; in this case, check the hose or pipe connections for leaks. If you have a vacuum relief valve/regulating system installed, it might be misadjusted or defective, requiring adjustment, repair, or replacement. A partially clogged screen in the suction connection or a filter on the suction connection could also be the cause; clean or replace them as needed. Additionally, check for partial clogging or lines with too small diameter in the suction, discharge, or pressure line, and remove any blockages or use larger diameter lines. The valve disk of the inlet non-return valve could be stuck, requiring disassembly and cleaning. If none of these ...

Summary

Safety Information

Intended Use

Defines handling and intended industrial use of the vacuum pump.

Safety Notes

Highlights potential hazards and safety notes with DANGER, WARNING, CAUTION.

Safety Concept

Explains safety concepts based on temperature and pressure monitoring.

Transport, Storage, and Installation

Installation prerequisites

Essential checks and conditions before installing the vacuum pump.

Mounting Position and Space

Requirements for the mounting location and surrounding space.

Suction Connection

Instructions and precautions for connecting the suction line.

Gas Discharge

Guidelines for connecting and managing the gas discharge.

Electrical Connection; Controls

Detailed instructions for electrical connections and controls.

Connecting Lines;Pipes

Instructions for connecting suction and discharge lines.

Checking the Function of the Measurement and Safety Instrumentation

Procedure to check the function of measurement and safety instruments.

Operating Notes and Maintenance

Maintenance Schedule

Schedule of maintenance tasks at different intervals.

Troubleshooting, Overhaul, and Disposal

Overhaul

Instructions and warnings regarding the overhaul of the vacuum pump.

Dismantling and Disposal

Instructions for dismantling and safe disposal of the vacuum pump.

Troubleshooting

Lists common faults, their causes, and recommended measures.

Spare Parts and Documentation

Spare Parts

Information on ordering spare parts and accessories.

Pressure Switch;indicator

Information and specifications for the optional pressure switch/indicator.

General Information and Safety (WIKA Instruments)

Safety

Details safety precautions and intended use for instruments.

Intended use

Specifies intended use for temperature measurement in hazardous areas.

Personnel qualification

Details requirements for skilled personnel performing work.

Additional safety instructions for instruments per ATEX and IECEx

Specific safety instructions for ATEX and IECEx certified instruments.

Special hazards

Warns about special hazards related to hazardous media and ESD.

Transport, Storage, and Commissioning

Commissioning, operation

General instructions for commissioning and operating the instrument.

Electrical Connections and Hazardous Area Operation

Resistance thermometer with terminal block

Electrical connection details for resistance thermometers with terminal blocks.

Resistance thermometer with cable or connector

Electrical connection details for resistance thermometers with cables/connectors.

Electrical connection of thermocouples

Instructions for electrically connecting thermocouples.

Thermocouples with terminal block

Details for connecting thermocouples with terminal blocks.

Thermocouples with cable or connector

Details for connecting thermocouples with cables or connectors.

Information on mounting and operation in hazardous area (Europe)

Guidelines for mounting and operating in hazardous areas in Europe.

General information on explosion protection

General information and requirements for explosion protection.

Hazardous Area Operations and Electrical Data

Special conditions of use (X conditions)

Details special conditions for safe use of instruments.

Ex marking

Explains Ex marking, temperature classes, and ambient ranges.

Temperature class classification, ambient temperatures

Details temperature class and ambient temperature ranges.

Mounting examples in hazardous areas

Examples of mounting methods in hazardous areas.

Electrical connection values

Electrical connection values for instruments.

Electrical data without built-in transmitter or digital display

Electrical data for instruments without built-in transmitters/displays.

Electrical Data, Calculations, and Maintenance

Sensor circuit in Ex ia or ib, IIC intrinsic safety ignition protection

Ignition protection for sensor circuits in Ex ia/ib IIC.

Electrical data for built-in transmitters or digital displays

Electrical data for instruments with built-in transmitters/displays.

Calculation examples for self-heating at the sensor;thermowell tip

Calculation examples for self-heating of sensor/thermowell tips.

Example

Example calculation for self-heating of an RTD sensor.

Calculation example for a sheathed cable with RTD sensor

Calculation example for self-heating of a sheathed RTD sensor.

Maintenance and cleaning

General maintenance and cleaning procedures for thermometers.

Maintenance

Details that thermometers are maintenance-free and require manufacturer repair.

Cleaning

Instructions for cleaning instruments, especially with moist cloths.

Faults

Lists common faults, their causes, and recommended measures.

Faults, Dismounting, Disposal, and Certificates

Dismounting, return and disposal

Instructions for dismantling and safe disposal of the instruments.

Dismounting

Warnings and instructions for dismounting instruments safely.

Disposal

Instructions for environmentally compatible disposal of instruments.

EC declaration of conformity

EC Declaration of Conformity for the instruments.

EC-Type Examination Certificate

Details of the EC-Type Examination Certificate for the equipment.

EC-Type Examination Certificate No. TÜV 10 ATEX 555793 X

Specific EC-Type Examination Certificate number.

EC-Type Examination Certificate Details

Certificate Schedules and Operation

Safety Instructions and Declarations

EC-Type Examination Certificates

SCHEDULE

Schedule for the EC-Type Examination Certificate.

EC-Type Examination Certificate Supplement

EC-Type Examination Certificate Supplement Details

Supplement to EC-Type Examination Certificate

EU Declaration of Conformity

Technical Data

BUSCH MINK MM 1144 BV Specifications

General IconGeneral
TypeRotary Vane Vacuum Pump
ModelMM 1144 BV
BrandBUSCH
Frequency50/60 Hz
Voltage230 V