Installation and
Operating Instructions
Vacuum Pumps
MINK MM 1324, 1202, 1252, 1322 AV
ATEX-Version
Busch Produktions GmbH
Schauinslandstr. 1
79689 Maulburg
Germany
0870145304 / 190709 / Original instructions / Modifications reserved

Table of Contents

Other manuals for BUSCH Mink MM 1202 AV

Questions and Answers

  • D
    Daryl TannerSep 13, 2025
    What to do if BUSCH Mink MM 1202 AV Water Pump starts but runs noisily?
    • J
      jessica73Sep 13, 2025
      If your BUSCH Water Pump starts but runs noisily or rattles, check for loose connections in the drive motor terminal box, ensuring all motor coils are properly connected according to the connection diagram, especially on motors with six coils. Tighten or replace any loose connections. Also, verify the pump is running in the correct direction. If these steps don't resolve the issue, the pump may need repair.
  • J
    jluceroAug 25, 2025
    Why does my BUSCH Mink MM 1202 AV start, but labours or runs noisily?
    • A
      Amanda FlynnAug 25, 2025
      If your BUSCH Water Pump starts but is running with laboring sounds, unusual noises or rattling, check for loose connections in the drive motor terminal box, ensuring all wires are properly connected according to the connection diagram, especially on motors with six coils; tighten or replace any loose connections. For three-phase motor versions, verify the pump isn't running in the wrong direction. If foreign objects are present or bearings are stuck, it is best to have the vacuum pump repaired by Busch service.
  • P
    Pamela WoodAug 26, 2025
    Why is my BUSCH Water Pump running so hot?
    • R
      ricegavinAug 26, 2025
      If the BUSCH Water Pump is running very hot, first ensure sufficient air ventilation by cleaning the fan cowlings, fan wheels, ventilation grilles, and cooling fins to remove any dust or dirt impeding cooling. If the pump is in a narrow space, ensure adequate ventilation. Also, check that the ambient and inlet gas temperatures are within permitted limits.
  • J
    Jay JohnsonAug 27, 2025
    Why is my BUSCH Water Pump so noisy?
    • E
      Edward RhodesAug 27, 2025
      If the BUSCH Water Pump is running very noisily, the issue could stem from defective bearings, which would require repair by Busch service. Another potential cause is a worn coupling element, which should be replaced. Low oil level or damage to the synchronizing gear can also cause noise, both of which necessitate repair by Busch service.
  • G
    George JonesAug 29, 2025
    What to do if BUSCH Mink MM 1202 AV Water Pump or the drive motor is blocked?
    • M
      Mitchell ThomasAug 29, 2025
      If the BUSCH Water Pump is blocked, ensure the drive motor is disconnected from the power supply. Remove the fan cover and try turning the drive motor with the vacuum pump by hand. If it remains frozen, remove the drive motor to check it and the vacuum pump separately. If the vacuum pump is blocked, it is best to have the vacuum pump repaired by Busch service.
  • R
    Robert DoyleAug 30, 2025
    What causes a BUSCH Water Pump to be blocked?
    • R
      Ronnie GallagherAug 30, 2025
      If your BUSCH Water Pump is blocked, it could be due to solid foreign matter entering the pump, requiring repair by Busch service; ensure the suction line has a screen, and consider adding a filter. Corrosion from remaining condensate can also cause blockage, necessitating repair by Busch service; check the process and consult the chapter on conveying condensable vapors. For three-phase motor versions, incorrect running direction can block the pump, requiring repair by Busch service; ensure correct direction upon connection.
  • E
    Eduardo SalazarNov 20, 2025
    How to troubleshoot low pressure in BUSCH Mink MM 1202 AV Water Pump?
    • C
      Cynthia LoweNov 20, 2025
      If the BUSCH Water Pump isn't reaching its usual pressure, several factors could be at play. Start by checking the hose or pipe connections for any leaks. If a vacuum relief valve/regulating system is installed, it might be misadjusted or defective, requiring adjustment, repair, or replacement. Also, inspect the screen in the suction connection for clogs and clean it, installing a filter upstream if frequent cleaning is needed. If there is a filter installed on the suction connection, ensure that it is clean. Check for partial clogging in the suction, discharge, or pressure line, and remove any obstructions. If the suction, discharge, or pressure line is too long with a small diameter, consider using a larger diameter. Inspect the valve disk of the inlet non-return valve to make sure it is...
  • R
    Ryan WhiteSep 14, 2025
    Why is my BUSCH Mink MM 1202 AV running so noisily?
    • W
      wendymaySep 14, 2025
      If your BUSCH Water Pump is running very noisily, this could be due to defective bearings or a worn coupling element. The synchronising gear could also be damaged due to operation with a low oil level or the synchronising gear is leaky.
  • D
    David FigueroaSep 8, 2025
    What to do if my BUSCH Mink MM 1202 AV does not reach the usual pressure on the suction connection?
    • O
      ojohnsonSep 8, 2025
      If your BUSCH Water Pump isn't reaching the usual pressure on the suction connection, check these items: * The inlet screen (IS) may be partially clogged. Clean the inlet screen (IS). * If equipped, the inlet filter cartridge might be partially clogged. Replace the inlet filter cartridge. * Internal parts may be worn or damaged. Contact Busch to repair the machine.
  • E
    erin14Sep 5, 2025
    Why is my BUSCH Water Pump running very noisily?
    • K
      Kelsey SchwartzSep 5, 2025
      If your BUSCH Water Pump is running noisily, it could be due to: * A worn coupling (CPL), which requires replacement. * Low oil level. In this case you should top up the oil. * Defective bearings. It is recommended to contact Busch to repair the machine.

Summary

Installation and Operating Instructions

Product Description

Use

Details on the intended application and operational limits of the vacuum pump.

Safety Concept

Operational Options; Use of Optionally Available Equipment

Information on using supplementary equipment with the vacuum pump.

Operation with Vacuum Relief Valve; Ambient Air Valve

Guidance on using optional valves for pressure control and system drying.

Principle of Operation

Cooling

Describes the methods used for cooling the vacuum pump during operation.

Safety

Intended Use

Defines the scope and purpose of handling the vacuum pump.

Safety Notes

Highlights potential hazards and safety warnings using DANGER, WARNING, CAUTION.

Transport

Transport in Packaging

Instructions for transporting the pump when it is packed on a pallet.

Storage

Conservation

Procedures for preserving the vacuum pump during storage, especially in adverse conditions.

Installation and Commissioning

Installation prerequisites

Critical checks and conditions that must be met before installing the pump.

Mounting Position and Space

Specifies requirements for the pump's location, including ambient conditions and clearances.

Suction Connection

Gas Discharge

Electrical Connection; Controls

Connecting Electrically

Essential safety warnings and procedures for electrical installation work by qualified personnel.

Connecting Lines;Pipes

Checking the Function of the Measurement and Safety Instrumentation

Operating Notes

Use

Reiterates intended use, ATEX area suitability, and conditions for operation.

Maintenance

Maintenance Schedule

Outlines maintenance intervals and tasks for monthly checks.

Troubleshooting

Spare Parts

Equipment Documentation Measurement and Safety Instrumentation

Overview

Details documentation for temperature measurement systems, including resistance and transmitter versions.

EU-Declaration of Conformity

Technical Data

2. Safety

2.3 Additional safety instructions for instruments per ATEX and IECEx

Crucial safety instructions for instruments with ATEX/IECEx approval to maintain explosion protection.

3. Specifications

3.1 Resistance thermometer

Provides technical specifications for resistance thermometers, including sensor connection and limiting errors.

6. Commissioning, operation

6.1 Electrical connection

Safety warnings and requirements for electrical connections, including grounding and cable protection.

7. Information on mounting and operation in hazardous area (Europe)

7.1 General information on explosion protection

General principles for explosion protection in hazardous areas, following ATEX directives.

8. Electrical connection values

8.1 Electrical data without built-in transmitter or digital display

Specifies maximum connection values for intrinsic safety in explosive gas atmospheres.

9. Calculation examples for self-heating at the sensor;thermowell tip

11. Faults

12. Dismounting, return and disposal

Appendix: EC declaration of conformity

Safety instructions

de Sicherheitshinweise für elektrische Betriebsmittel für explosionsgefährdete Bereiche...

Safety guidelines for electrical apparatus in explosion-hazardous areas according to ATEX.

EC-TYPE-EXAMINATION CERTIFICATE

Schedule to EC-TYPE-EXAMINATION CERTIFICATE

Supplement

BUSCH Mink MM 1202 AV Specifications

General IconGeneral
BrandBUSCH
ModelMink MM 1202 AV
CategoryWater Pump
LanguageEnglish