11 | Troubleshooting
16 / 24 0870145123_SB0050-1400D0_D2_A0000_IM_en
The machine does not reach
the usual pressure on the
suction connection.
Suction or discharge lines
too long or section diameter
too small.
Use larger diameter or
shorter lines.
Seek advice from your
local Busch representa-
tive.
The machine runs in the
wrong direction.
Check the direction of ro-
tation, see Wiring Dia-
gram Three-Phase Motor
Different density of con-
veyed medium
Take conversion of pres-
sure value into account.
Contact Busch if neces-
sary.
Change in blade profile due
soiling.
Check the impeller, clean
or replace if necessary.
In case an inlet screen is in-
stalled:
The inlet screen is partially
clogged.
Clean the inlet screen.
In case a vacuum relief valve
is installed:
The vacuum relief valve is
misadjusted or defective.
Replace the vacuum relief
valve.
In case an inlet filter valve is
installed:
The inlet filter cartridge is
partially clogged.
Replace the inlet filter
cartridge.
Leak in the system. Repair leak.
Internal parts are worn or
damaged.
Repair the machine (con-
tact Busch).
The machine runs too hot. Insufficient cooling. Remove dust and dirt
from the machine.
Ambient temperature too
high.
Observe the permitted
ambient temperature.
Compressor leaky. Seals on silencer defective. Check silencer seals and
replace if necessary
Seals in motor area defect-
ive.
Check motor seals and re-
place if necessary
For the solution of problems not mentioned in the troubleshooting chart contact your
Busch representative.