BW T bestaqua 60 - 62
Reverse Osmosis Plant
Installation and Operating manual EN

Questions and Answers

  • Y
    Yolanda MedinaAug 16, 2025
    What to do if BWT bestaqua 61 LT Water Filtration Systems show NO WATER ALARM?
    • Y
      ygarciaAug 16, 2025
      If the BWT Water Filtration System displays a 'NO WATER ALARM', it indicates a lack of water supply. This can be due to several reasons: * Closed shut-off valves or other obstructions at the inlet. Ensure the main stop valves are open and check the water supply. * Insufficient water supply pressure. Verify that the water supply pressure is between 3.0 to 6.0 bar. * A blocked pre-filter. If necessary, replace the pre-filter.
  • P
    pwilkinsAug 19, 2025
    What to do if BWT Water Filtration Systems show HP OVER PRESSURE?
    • J
      Jill WoodsAug 19, 2025
      If your BWT Water Filtration System shows 'HP OVER PRESSURE', it means the pressure is too high. To resolve this, open the recirculation valve until the pressure drops below 15 bar, ensuring the permeate/concentrate flow is correctly adjusted.
  • D
    Donald McdowellAug 22, 2025
    What causes HP FUSE to burn in BWT bestaqua 61 LT Water Filtration Systems?
    • M
      Mary PetersonAug 22, 2025
      If your BWT Water Filtration System displays 'FAULT 7: HP FUSE BURNED', it usually indicates an issue with the pump. The possible causes include: * A defective pump. * A motor fault; check the operating parameters. * The pump being mechanically blocked or damaged. * The HP Pump fuse itself being burned. In any of these cases, replace the fuse.
  • E
    Eric ShieldsAug 25, 2025
    Why does my BWT bestaqua 61 LT show CONDUCTIVITY is too high?
    • D
      Derrick BrockAug 26, 2025
      If your BWT Water Filtration System displays 'FAULT 2: CONDUCTIVITY is too high', it means the conductivity level has exceeded the preset alarm limit. This can be due to: * Exceeding the preset alarm limit. In this case, increase the alarm limit value, or consider changing the module if that's not possible. * Fluctuating feed water quality. Increase the alarm limit value, or consider changing the module if that's not possible. * Defective RO membranes. Increase the alarm limit value, or consider changing the module if that's not possible.
  • B
    Brian KennedyAug 28, 2025
    What to do if BWT bestaqua 61 LT Water Filtration Systems show PEMEATE FLOW ALARM?
    • K
      Kathryn SpenceAug 28, 2025
      If your BWT Water Filtration System shows 'FAULT 6: PEMEATE FLOW ALARM', it indicates that the permeate flow is outside the acceptable range. This can happen if the preset alarm limit has been exceeded, so increase the alarm limit value. Alternatively, the membranes might need replacement.
  • A
    Anthony RossAug 31, 2025
    How to fix HP PRESSURE TRASMITTER ERROR in BWT bestaqua 61 LT Water Filtration Systems?
    • O
      ovargasAug 31, 2025
      If your BWT Water Filtration System displays 'FAULT 3: HP PRESSURE TRASMITTER ERROR', it indicates a problem with the high-pressure transmitter. This could be due to a defective pressure sensor (permeate) or a damaged cable (wire rupture). In either case, replace the pressure sensor or Multiblock.
  • T
    Terry MeyerSep 2, 2025
    How to fix TP RESSURE TRASMITTER ERROR in BWT bestaqua 61 LT?
    • S
      Susan PottsSep 3, 2025
      If your BWT Water Filtration System displays 'FAULT 4: TP RESSURE TRASMITTER ERROR', it indicates an issue with the pressure transmitter. This can be caused by a defective pressure sensor or a damaged cable (wire rupture). To resolve this, replace the pressure sensor or Multiblock.
  • T
    terry59Sep 5, 2025
    What does INLET CONDUCTIVITY ALARM mean in BWT bestaqua 61 LT?
    • P
      Paul KentSep 6, 2025
      If your BWT Water Filtration System displays 'FAULT 11: INLET CONDUCTIVITY ALARM', it means the inlet conductivity is too low. To solve this, check and replace the conductivity sensor or Multiblock.
  • E
    Elizabeth ValentineSep 9, 2025
    What to do if TP FUSE BURNED in BWT Water Filtration Systems?
    • K
      Kristen WatkinsSep 9, 2025
      If your BWT Water Filtration System displays 'FAULT 8: TP FUSE BURNED', it means the TP Pump fuse has burned out. Replace the fuse.
  • W
    wwilliamsSep 12, 2025
    What causes INLET FLOW WATER TOO LOW in BWT bestaqua 61 LT Water Filtration Systems?
    • S
      stacy19Sep 12, 2025
      If your BWT Water Filtration System shows 'FAULT 13: INLET FLOW WATER TOO LOW', it indicates insufficient water flow at the inlet. This can be due to a clogged 5ยต pre-filter (replace it), a bent inlet hose (straighten it), or a defective inlet solenoid valve (replace it).

Summary

3 Function descriptions

3.1 Permeate production

Explains how the RO unit produces permeate and manages concentrate.

5 Water quality

6.1 Connection of feed water (inlet water)

Details on connecting the feed water supply to the RO unit.

6.2 Connection of outlet hose

Instructions for connecting the permeate outlet hose.

6.4 Connection of permeate (treated water)

Instructions for connecting the treated water outlet.

7 Electrical connections

Instructions for safely connecting the RO unit to the power supply.

8 Function buttons og display elements

Display Elements and Indicators

Details on the RO unit's display screen and status indicators.

Control Buttons and Functions

Explanation of the control buttons and their functions.

8.7 Menu: MAINTENANCE

Accessing maintenance functions and schedules.

9 Start-up of the RO unit

10 Automatic functions

11 Maintenance and troubleshooting

11.1 Maintenance

Overview of regular maintenance tasks and intervals.

11.2 Replacement of membranes

Detailed steps for replacing the RO membranes.

11.4 Troubleshooting

Guidance on identifying and resolving common faults and alarms.

13 Appendix

13.5 Start-up control

A checklist for verifying correct installation and startup procedures.

BWT bestaqua 61 LT Specifications

General IconGeneral
BrandBWT
Modelbestaqua 61 LT
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals