EasyManua.ls Logo

BYD Battery-Box Premium LVL User Manual

BYD Battery-Box Premium LVL
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
BYD Battery-Box Premium LVL
Service Guideline and Checklist
Version 1.1
Valid forPremium LVL 15.4
LVL 15.4 (max. 64 per system) BMU (1 x per system)
Make sure to always use the latest version of this service document,
available at: www.bydbatterybox.com
Important: The installation and all other kinds of works or measurements in combination with the Battery-Box
Premium are only allowed by professional and qualified electricians.
This checklist is a shortened assistance for the Battery-Box and does not replace the original manual, which can
be found on www.bydbatterybox.com / www.eft-systems.de / www.alpspower.com.au. Subject to technical
modifications; no responsibility is accepted for the accuracy of this information. Attention: Improper handling
can cause danger and damage.
Question and Answer IconNeed help?

Do you have a question about the BYD Battery-Box Premium LVL and is the answer not in the manual?

BYD Battery-Box Premium LVL Specifications

General IconGeneral
Battery TypeLithium Iron Phosphate (LFP)
Nominal Voltage51.2 V
Max Charge Current100 A
Operating Temperature-10°C to +50°C
Warranty10 years
IP RatingIP55
Operating Voltage44.8 V - 57.6 V
ScalabilityUp to 64 modules in parallel
CommunicationCAN
Cycle Life6000 cycles
Efficiency>95%

Summary

GENERAL STEPS

1.1 Configuration

Check system configuration and inverter settings for correct operation.

1.2 Correct internal cabling

Ensure internal wiring connections are correctly made as per manual.

1.3 Correct external cabling

Verify external communication and power cables are properly connected.

1.4 Latest Firmware

Importance of updating the battery system to the newest firmware version.

1.5 App Configuration

Mandatory configuration of the battery system using the "BYD Be Connect" App.

1.6 Restart

Procedure for safely restarting the battery system after configuration.

1.7 Switch on procedure

Correct sequence for switching on the battery and inverter for operation.

1.8 Correct Operation

How to verify the system is operating correctly by checking SOC and charge/discharge.

ERROR ANALYSIS

2.1 BMU shows no reaction / No LED

Troubleshooting steps for when the BMU's LEDs do not light up.

2.2 Communication problem with Inverter

Steps to diagnose and resolve communication issues between battery and inverter.

2.3 Problem with the Firmware Update / App Configuration

Solutions for errors encountered during firmware updates or app configuration.

2.4 BMU/BMS LED event code (EC)

Interpreting BMU/BMS LED event codes to diagnose system errors.

2.5 Be Connect Plus (BCP)

Using the PC tool Be Connect Plus for system analysis and data logging.

2.6 Voltage measurement and undervoltage

Procedures for measuring module/cell voltages and diagnosing undervoltage issues.

SERVICE TASKS

3.1 BMU Replacement

Instructions for replacing a faulty BMU unit.

3.2 BMS Replacement

Guidance on replacing the BMS drawer.

3.3 BIC Replacement

Instructions for replacing the BIC board.

SERVICE CHECKLIST AND CONTACT INFORMATION

Related product manuals