SeQual
®
Eclipse 5
®
Transportable Oxygen Concentrator with autoSAT
®
Quick RefeRence Guide
Recharge Time
1. The typical time to recharge the battery inside the Eclipse
on AC or DC power is between 2–5 hours, dependent
upon the flow setting.
The battery may be re-charged while the Eclipse is either
ON or OFF.
2. The battery will recharge using the optional desktop
charger in approximately 3 hours.
3. It is acceptable to leave the Eclipse plugged into AC
power at all times while it is OFF. Note that while the
unit remains plugged in and OFF, the internal fan may
continue to run while the battery is charging and produce
a faint humming noise.
Battery Gauge
The Eclipse 5 has a battery status gauge on the right side
of the display screen. Each of the 5 horizontal gray bars
represents approximately 20% of the total battery charge.
When a battery is being charged, the indicator bars will blink
in a waterfall-type fashion. If a battery is not installed, or is
improperly installed, the battery status gauge will not appear
on the screen.
On/Off
Press and hold the ON/OFF button (top left Blue Button) for
two seconds to power on the Eclipse 5. Upon power up, the
audible alarm should sound for 3 seconds, and all three lights
on above the display screen should illuminate. It is normal for
the yellow and/or red lights to remain on for up to 5 minutes
during warm-up. Once warm-up is complete, only the green
light should be on. Press and hold the ON/OFF button for two
seconds to power off the Eclipse 5.
Changing Flow Mode
Press the flow mode button (bottom left blue button) to toggle
between pulse and continuous flow. The light adjacent to
the button will illuminate when in pulse mode and will blink
with each breath detection and delivery. If the unit is in pulse
mode but does not detect a breath, it will switch to continuous
mode.
Battery Life
Continuous Flow Pulse Flow
0.5 LPM – 4.4 Hours 2.0 LPM – 2.0 Hours 1.0 (16 mL) – 5.4 Hours 4.0 (64 mL) – 4.0 Hours 7.0 (128 mL) – 2.5 Hours
1.0 LPM – 3.7 Hours 3.0 LPM – 1.3 Hours 2.0 (32 mL) – 5.1 Hours 5.0 (80 mL) – 3.7 Hours 8.0 (160 mL) – 2.0 Hours
3.0 (48 mL) – 4.9 Hours 6.0 (96 mL) – 3.5 Hours 9.0 (192 mL) – 1.7 Hours
NOTE: Pulse flow times are calculated based on 12BPM. Higher breath rates will decrease battery times on pulse mode only.
Question and Answer IconNeed help?

Do you have a question about the CAIRE SeQual Eclipse 5 and is the answer not in the manual?

CAIRE SeQual Eclipse 5 Specifications

General IconGeneral
Device TypePortable Oxygen Concentrator
AC Power100-240V, 50/60Hz
Operating Temperature41°F to 104°F (5°C to 40°C)
Oxygen OutputUp to 3 LPM (liters per minute)
Oxygen Concentration87% to 96%
Weight18 lbs (8.2 kg)
Battery Durationup to 5 hours
Power SupplyAC and DC
DC Power12V
Operating AltitudeUp to 10, 000 feet (3, 048 meters)
Input Power100 to 240 VAC, 50/60 Hz; 12 VDC
Operating ModesContinuous Flow and Pulse Dose

Summary

Recharge Time

Typical Recharge Duration

Battery recharges in 2-5 hours on AC or DC power, depending on flow setting. Can recharge while unit is ON or OFF.

Desktop Charger

Recharges the battery in approximately 3 hours using the optional desktop charger.

Continuous AC Connection

Acceptable to leave unit plugged into AC power when OFF. Internal fan may run during charging.

Battery Gauge

Battery Status Indicator

Five horizontal bars indicate charge (~20% each). Bars blink during charging. Not shown if battery absent.

On/Off Operation

Powering On and Off

Press and hold the ON/OFF button for two seconds to power on/off. Warm-up lights are normal during startup.

Flow Mode Control

Changing Flow Mode

Toggle between pulse/continuous flow using the flow mode button. Unit auto-switches if no breath detected.

Power Supplies

AC Power Supply

Runs unit at all flow rates and recharges battery. Auto-adjusts voltage for travel. Green LED on brick.

DC Power Supply

Powers unit from automotive outlet. Recharges battery at 2.0 LPM or lower/pulse settings. Green LED on brick.

Maintenance and Accessories

Air Intake Filter

Remove and clean weekly with soap and water. Allow to dry thoroughly before re-installing.

Nasal Cannula and Tubing

Use standard cannula. Max tubing length: 50 ft (continuous), 7 ft (pulse or humidifier).

Humidifier Bottle Usage

Use with continuous flow settings ONLY when the unit is stationary. Must be removed when moving unit.