ACCESSORIES
Accessories
Ingredient caddy
Ref. IC4 (4 bay)
Shelf unit
Ref. SHU
Fused spur time switch
Ref. 7DFST
Max 3 kW
Plug-in time switch
Ref. 7DPIT
Max 3 kW
Water filter kit
(To reduce taste & odour problems)
Ref. 10TOSCK
Ref. 10TOSC
(Filter & timestrip replacement for
kit shown above)
For more information visit our website at www.calomax.co.uk or call 0113 249 6681
Securing clamp kit
- 3C5 & 3C10 only
Ref. MFK
X4
BASIC TROUBLE SHOOTING
Symptoms Possible Cause Remedy
No boiling water
available
Broken tap top
Element failed or tripped
Defective Printed Circuit Board
Replace tap top (or component)
Replace element or reset
Replace Circuit Board
Overboiling
Excessive internal scale. (See
De-Scale’ page 19)
Faulty wiring to thermistor /
faulty thermistor
Temperature controller needs
adjusting
Element failed to earth
Defective Printed Circuit Board
De-scale the boiler
(Particularly thermistor)
Repair / replace as required
Lower operating temperature
Replace element
Replace Circuit Board
Overfl ows
Dirt in solenoid valve.
Level sensors require de-
scaling or replacing
Defective Printed Circuit Board
Clean solenoid lter or replace
solenoid, “work the boiler” -
see Service Instructions.
De-scale / replace sensors
Replace Circuit board
Element thermal cutout.
The Eclipse range of boilers has an inbuilt thermal cutout device to protect the
element in a boil dry situation. Should the cutout be activated, contact an approved
Calomax service provider for advice.

Related product manuals