SECTION 11: FLOWSENSE® (-FL) ®
making
since 1986
w
ater work
1. Press the ON-AT-A-TIME Menu key.
The STATIONS ON-AT-A-TIME screen is displayed
(Figure 11.11).
PROG A . . . . . . . . . . . . . . 1 1
An "X" means don't use this
On-At-A-Time as a limit
PROG D . . . . . . . . . . . . . . 1 1
PROG E . . . . . . . . . . . . . . 1 1
DRIP 1 . . . . . . . . . . . . . 1 1
DRIP 2 . . . . . . . . . . . . . 1 1
PROG C . . . . . . . . . . . . . . 1 1
STATIONS ON-AT-A-TIME
Within Within
Program System
PROG B . . . . . . . . . . . . . . 1 1
Figure 11.11
2.
Press the blue ARROW keys to move
the cursor to the Program and Within
Program setting desired.
Note:
The default setting is set to 1 on all programs
and within system.
3. Press the PLUS or MINUS keys for any
number to change the setting.
WITHIN PROGRAM:
This section allows
you to choose the amount of valves that you
want to set as a limit to come on at a time
within a program.
WITHIN CONTROLLER: This section
allows you to choose the amount of valves
that you want to set as a limit to come on at
a time within the controller.
Example:
Within Program
Within Controller
Program A 1 2
Program B 1 2
This example allows the user to set up one (1) valve
on at a time for Programs A and B. The controller
will allow both Programs to have one (1) valve each
run simultaneously for a total of two (2) on within
controller.
Example:
Within Program
Within Controller
Program A 1 1
Program B 3 3
This example allows the user to set up one (1) valve
on at a time for Programs A. The controller will only
allow one valve to operate while program A is
running. Program B is set up to operate 3 valves on
at a time, and will only operate up to three valves
when Program B is running.
4. Press the BACK key to return to the
FLOW METER, MASTER VALVE, &
PUMP screen (Figure 11.5).
THIS CONCLUDES THE FLOWSENSE®
SECTION