Chapter 4: Reference information Country specific band range maximum transmit
power
Page
4-75
Table 184 Default combined transmit power per Country – 5.2 GHz band PMP 450m Series
USA,
Other FCC
AP Sector 5 MHz 24
10 MHz 27
15 MHz 28
20 MHz 30
30 MHz 30
40 MHz 30
Mexico Any Any 5 MHz 24
10 MHz 27
15 MHz 28
20 MHz 30
30 MHz 30
40 MHz 30
Other Any Any 5 MHz 42
10 MHz 42
15 MHz 42
20 MHz 42
30 MHz 42
40 MHz 42
Note
For releases 16.0 and later, although sector transmission mode EIRP is limited to 42
dBm, ROW GUI configuration limit allows a setting of up to 48 dBm. This allows the
software to transmit as high as 48 dBm for ROW regions, depending on the
modulation mode and transmission mode in use. For a detailed explanation, see the
Release 16.0 training slides available at:
https://learning.cambiumnetworks.com/learn/course/121/PMP450SoftwareRelease16