p. 18 - Manual FB00802-EN v. 1- 07/2017 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice.
• Device for home and oce use.
• Independently mounted electronic device.
• LCD Display .
• Power supply: three alkaline LR6 1.5V AA
batteries.
• Battery life: over 1 year.
• Relay switch: maximum voltage 250 V,
maximum current 5A with resistive load
(2A with inductive load).
• Type of action: 1B-U.
• Room-temperature detection interval: 15 s.
• Temperature dierential: from ±0.1 °C to
±0.9 °C, selectable.
• Reading resolution: 0.1 °C.
• Reading range displayed: from 0 °C to
+40 °C.
• Precision: ≤ ±0.3 °C.
• Class A software.
• Pollution rating: 2.
• Impulse voltage: 4 kV.
• Maximum temperature of the control
head: 40 °C.
• Operating temperature: from 0 °C to +40
°C.
• Protection rating: IP30.
• Dimensions: 132x82x33.5 mm.
Technical features
Problem solving
Press the R reset button if there are
any malfunctions.
This procedure restores the device
to its factory settings.
An error message on the display
(
) followed by a number ,
means that one of the 00 to 25
cursors is in the wrong position.
Realign the flagged cursor to
restore the device to normal op
-
erating mode.