14
14 - Manual:
FA00613-EN
FA00613-EN v.
1
1 - 11/2016 - © CAME S.p.A. The data and information in this manual may be changed at any time and without notice.
F-1 Create a MASTER card for function programming with a transponder card.
F-2
Create a new card (up to 500 cards).
F-3
Delete a card.
Select the number assigned to the card to delete using the key or place the card on the transponder (SENSOR 1); the display will show the card
number. Press ENTER to confi rm deletion.
F-4
Delete all cards
F-5
Set standby time.
After an open command is relayed via key (2-3 / 2-4) or transponder, the turnstile will remain unlocked for a time that can be set between 10
to 60 seconds.
F-6
Call info onto the display screen
The user can select the type of information to view on the display: number of entrances/exits, time or neither of the two.
F-7
Clear number of passages (entrances-exits through the turnstile)
F-8
Set maximum number of entrances/exits allowed in the direction defi ned with F-13.
From 1 to 65,000 or unlimited (selecting OFF).
F-9
Set date and time.
It is possible to select automatic setting of daylight saving time (ON) or standard time (OFF).
F-10
Buzzer
The intruder alert buzzer can be activated or deactivated.
The buzzer sound can be set from 1 to 60 seconds.
F-11
StandAlone / OnLine Operating mode
StandAlone Mode)
Online Mode the turnstile is Controled by an access control system (RBM84).
F-12
Device number.
A device number can be assigned to each turnstile.
F-13
Set opening direction.
The direction set is indicated by the display arrow.
F-14
Antipassback Mode.
Enables or disables the antipassback function.
Prevents access to an area when the person is already within the confi nes. This function avoids the use of a card for two or more consecutive
accesses to the same area.
F-15
Independent entrance/exit control. Only with F-11 in StandAlone mode.
Free
free access
Restricted
acceded denied
Controled
access allowed only to enabled users
OFF
access allowed only to authorised users
Settable modes:
Entrance
exit
Controled
Controled
Restricted
free
Free
restricted
Restricted
Controled
Controled
restricted
Free
Controled
Controled
free
Excludes enabling of F-8 and F-14
F-16
Data storage to Memory Roll.
F-17
Read data in Memory Roll.
Function menu