001V06003 Chain guide T = 4.02 m.
- Spring-balanced overhead doors up to 3.25 m in height.
- Sectional* doors up to 3.20 m in height.
001V06005 Belt guide T = 3.02 m.
Counter-balanced overhead doors up to 2.4 m in height
- Counter-balanced overhead doors up to 2.25 m in height
- Sectional* doors up to 2.20 m in height.
001
001V06006 Belt guide T = 3.52 m.
- Counter-balanced overhead doors up to 2.75 m in height.
- Sectional* doors up to 2.70 m in height.
001V06007
Belt guide T = 4.02 m.
- Spring-balanced overhead doors up to 3.25 m in height
- Sectional* doors up to 3.20 m in height.
Optional accessories
001
001V201 Transmission arm for counter-balanced overhead doors.
001V121 Pull-cord release device to apply onto handle.
For sectional doors, see the APPLICATION EXAMPLES paragraph.
GENERAL INSTRUCTIONS FOR INSTALLING
Only skilled, qualified staff must install this product.
If the door is fitted with a pedestrian door, you must also fit a safety switch at the entrance, to stop the
operator from working when the pedestrian door is open.
Preliminary checks
Before beginning, do the following:
make sure you have set up a suitable dual pole cut off device along the power supply that is compliant
with the installation rules. It should completely cut off the power supply according to category III surcharge
conditions (that is, with minimum contact openings of 3 mm);
Setup suitable tubes and conduits for the electric cables to pass through, making sure they are protected
from any mechanical damage;
make sure that any connections inside the container (ones that ensure continuity to the protection
circuit) are fitted with additional insulation with respect to those of other electrical parts inside:
make sure that the door is properly balanced. When stopped at any point, it must maintain its position.