How to troubleshoot a CAME V6000P that neither opens nor closes?
- RRichard HigginsAug 21, 2025
If your CAME Garage Door Opener isn't opening or closing, start by checking the power supply. Also, verify that the (1-2) NC safety contact is not open.
How to troubleshoot a CAME V6000P that neither opens nor closes?
If your CAME Garage Door Opener isn't opening or closing, start by checking the power supply. Also, verify that the (1-2) NC safety contact is not open.
What to do if my CAME V6000P Garage Door Opener opens but won't close?
If your CAME Garage Door Opener opens but does not close, it could be due to several reasons. First, check if the N.C. safety contact (2-C1) is open. Also, ensure the door travel direction is correct and verify the balancing of the overhead garage door.
Why doesn't my CAME V6000P Garage Door Opener automatically close?
If your CAME Garage Door Opener is not performing the automatic closing function, verify that the automatic closing function is active and check the proper direction of the door travel.
How to fix a CAME Garage Door Opener transmitter that is not working?
If your CAME Garage Door Opener transmitter isn't working, try memorizing the transmitter again.
What to do if my CAME V6000P Garage Door Opener closes but doesn't open?
If your CAME Garage Door Opener operator closes but does not open, check the balancing of the overhead garage-door.
Why CAME Garage Door Opener opens but doesn't close?
If your CAME Garage Door Opener opens but does not close, check the N.C. safety contact (2-C1) and also check the proper direction of the door travel. You should also check the balancing of the overhead garage-door.
Why CAME Garage Door Opener closes but doesn't open?
If your CAME Garage Door Opener closes but does not open, you should check the balancing of the overhead garage-door.
What to do if CAME Garage Door Opener does not perform automatic closing?
If your CAME Garage Door Opener does not perform the automatic closing, check that the automatic closing function is active and check the proper direction of the door travel.
Max. door weight | 600 kg |
---|---|
Max. door width | 6 m |
Duty cycle | 30% |
Power supply | 230 V AC |
Motor Type | DC |
Remote Control | Yes |
Defines the primary purpose and application for V6000P and V1000P operators.
Essential checks to perform before beginning the installation process to ensure safety and proper setup.
Step-by-step instructions for fitting the brace to the transmission guide using supplied hardware.
Guidance on correctly positioning the traction guide for different types of garage doors.
Details on how to securely attach the traction guide to the doorway and ceiling.
Instructions for attaching the transmission arm brace to the door's upper beam.
Explains how to attach the operator unit to the guide rail in standard or right-angle positions.
Procedure for repositioning the micro switch within the operator unit for specific configurations.
Steps to prepare the operator and programming device for initial setup and configuration.
Explains the function of each key on the programming device and symbols used.
Provides a key to understanding the various symbols displayed on the operator and programming device.
Step-by-step guide to setting the upper travel limit for the garage door.
Step-by-step guide to setting the lower travel limit for the garage door.
Procedure to verify that the operator has correctly learned the door's travel limits.
Crucial final step to save all configured settings and parameters in the operator's memory.
How to set the sensitivity for the obstacle detection system to prevent malfunctions and ensure safety.
Instructions to activate an audible alarm that sounds if the door remains open for an extended period.
Configures the delay period before the door automatically closes after opening.
Final step to save programming settings, ensuring they are not lost.
Activates a warning signal after 2,000 cycles, indicating the need for mechanical maintenance.
Enables a sound and light warning 20 seconds before automatic door closing.
Instructions for connecting an external antenna to improve radio signal reception.
Steps for installing the AF (radio frequency) card onto the control board.
Guide to programming remote control transmitters to operate the garage door operator.
Procedure to remove programmed remote control transmitters from the operator's memory.
Guidelines and log for routine checks and upkeep of the operator system every six months.
Log for recording significant maintenance, repairs, or improvements performed by specialized technicians.
Instructions for the responsible disposal and recycling of packaging materials.
Guidelines for the correct and safe disposal of the operator unit and its components.
Indicates compliance with current applicable standards and regulations for the product.