Page 21 - Manual FA01799 -EN - 04/2022 - © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Memorizing the programming
⚠It is OBLIGATORY to conclude the programming procedures with this function so as not to lose
any saved settings!
Press + to select 5.
Press P. The display segments rotate clockwise.
The programming has been memorized.
1
RÒ
Press P for about five seconds, 1 appears.
2
Press + and select 4.
3 Press P, appears.
4 Press + o - to set the suitable sensitivity level.
5
Minimum Sensitivity level Maximum
6 Press P to save the procedure.
Adjust the obstruction detection sensitivity during boom travel
The door must be properly balanced. If the sensitivity is too low it could cause the door to malfunction.
Change the parameter in compliance with the regulations on impact force EN 12453.
By default, the sensitivity is set to a medium level. To increase or reduce sensitivity:
The last phase of programming must always be memorized (function 5).
Once memorization is complete, perform two opening and closing cycles to confirm that the settings have been
saved.
Page 21 - Manual FA01799 -EN - 04/2022 - © Came S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructions

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CAME V6000P and is the answer not in the manual?

CAME V6000P Specifications

General IconGeneral
BrandCAME
ModelV6000P
CategoryGarage Door Opener
LanguageEnglish

Related product manuals