Troubleshooting Chart (Continued)
Excessive moisture in 1. Excessive water in tank
discharge air 2. High humidity
FP2200 Series
1. Drain tank
2. Move to area of less humidity; use air line filter
Compressor runs 1. Defective pressure switch 1. Replace switch
continuously 2. Excessive air usage 2. Decrease air usage; compressor not large enough for
air requirement
Excessive starting and
stopping (auto start)
1. Excessive condensation in tank
2. Air leaks in piping (on machine or in
outside system)
3. Tank check valve leaking
1. Drain more often
2. Replace leaking components or tighten as necessary
3. Replace or repair as necessary
DO not disassemble check valve
¥!_wlA_L_;I with air in tank; bleed tank
Air leaking from Check valve stuck in an open position
unloader on pressure
switch
Remove and replace check valve
DO not disassemble check valve
¥!'lil#±tt'_Ll'l =1_t with air in tank; bleed tank
Motor runs but no air Belt broken
output
Replace belt