CR300-Series Datalogger 
13 
Add measurements to the table by 
selecting them under Selected 
Sensors and then clicking on an 
output processing option in the 
center column of buttons. 
Click Finish to compile the 
program. Give the program a name. 
A summary screen will appear 
showing the compiler results. Any 
errors during compiling will be 
displayed. 
 
If LoggerNet, PC400, or PC200W is 
running on your PC, and the PC-to-
datalogger connection is active, you 
can choose to send the program. See 
Section 
4.1, Configure Software (p. 
3)
, for setting up an active PC-to-
datalogger connection with 
datalogger support software. 
 
 
Select BattV under Selected Sensors and then click Average. Repeat this procedure for PTemp_C and Temp_C. 
Give the program the name MyTemperature. Save it in the default C:\CampbellSci\SCWin folder. Do not send the 
program at this time. 
Click No. Do not send the program here. You will do this in Section 4.5, Send a Program (p. 14).