EasyManua.ls Logo

Campbell CR300 series - 18.3 Resistance measurements

Campbell CR300 series
321 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sensor type Connection example
4-wire transmitter using data logger power
4-wire transmitter using external power
18.3 Resistance measurements
Bridge resistance is determined by measuring the difference between a known voltage applied to
the excitation (input) of a resistor bridge and the voltage measured on the output arm. The data
logger supplies a precise voltage excitation via VX terminals. Return voltage is measured on
analog input terminals configured for single-ended (SE) or differential (DIFF) input. The result of
the measurement is a ratio of measured voltages.
See also Resistance measurement specifications(p. 245).
18.3.1 Resistance measurements with voltage excitation
CRBasic instructions for measuring resistance with voltage excitation include:
l
BrHalf() - half bridge
l
BrHalf3W() - three-wire half bridge
l
BrHalf4W() - four-wire half bridge
18. Measurements95

Table of Contents

Other manuals for Campbell CR300 series

Related product manuals