23.3.59.4 CellKeepAlive
URL for ping to verify network connectivity. This is only sent if there has been no network activity
within the CellKeepAliveTime setting. If there is no ping response, the network connection is re-
established. To disable keep alive pings, leave this setting blank.
l
String data type
Where to find:
l
Settings Editor tab in Device Configuration Utility: Cellular > PingKeep Alive URL
23.3.59.5 CellKeepAliveTime
Ping keep alive timeout (in seconds).
l
Long data type
Where to find:
l
Settings Editor tab in Device Configuration Utility: Cellular > Ping Keep Alive Timeout Value
23.3.59.6 CellPDPAuth
Specifies the PDP authentication type (if used). PDP Authentication is only used if there is a PDP
Username and Password ANDthe PAP or CHAP authentication is required. If a
PDPAuthentication Type is required, it will be provided by your cellular provider with the APN. 0
None, 1 PAP, 2 CHAP
l
Long data type
Where to find:
l
Settings Editor tab in Device Configuration Utility: Cellular > PDPAuthentication Type, PPP
Authentication User Name, PPPAuthentication Password
23.3.59.7 CellPDPPassword
Specifies the PDP password used for authentication. Often there is no password, and this field
can be left blank. If a password is required, it will be provided by your cellular provider with the
APN.
l
String data type
23. Information tables and settings (advanced)224