l
String data type
23.3.48 RS232Power
Controls whether the RS-232 port will remain active even when communications are not taking
place.
l
Boolean data type
23.3.49 Security(1), Security(2), Security(3)
An array of three security codes. A value of zero for a given level will grant access to that level's
privileges for any given security code. For more information, see Data logger security(p. 144).
23.3.50 ServicesEnabled
Discontinued; replaced by/aliased to HTTPEnabled, PingEnabled, TelnetEnabled.
23.3.51 TCPClientConnections
Discontinued; replaced by / aliased to PakBusTCPClients.
23.3.52 TCPPort
Discontinued; replaced by / aliased to PakBusPort.
23.3.53 TelnetEnabled
Enables (1) or disables (0) the Telnet service.
23.3.54 TLSConnections (Max TLS Server Connections)
This setting controls the number of concurrent TLS (secure or encrypted) client socket
connections that the data logger will be capable of handling at any given time. This will affect
FTPS and HTTPS services. This count will be increased by the number of DNP() instructions in the
data logger program.
This setting will control the amount of RAM that the data logger will use for TLS connections. For
every connection, approximately 20KBytes of RAM will be required. This will affect the amount of