Table 6-2: SDI-12 pin-out, wire color, function, and data logger connection
Wire color Pin-out Function Data logger connection
Green 9 SDI-12 signal
C, SDI-12, or
U configured for SDI-12
1
Red 2 Power 12V
Black 3, 1 Power and signal ground G
Clear NC Shield G
1
U and C terminals are automatically configured by the measurement instruction.
For CR6 and CR1000X data loggers, triggering conflicts may occur when a companion terminal is
used for a triggering instruction such as TimerInput(), PulseCount(), or WaitDigTrig().
For example, if this product is connected to C3 on a CR1000X, C4 cannot be used in the
TimerInput(), PulseCount(), or WaitDigTrig() instructions.
6.1.3 RS-232 wiring
The RS-232 output can be directly read by a CR6 or CR1000X data logger (Table 6-3 [p. 11]).
Table 6-3: RS-232 pin-out, wire color, function, and data logger connection
Wire Color Pin-out Function Data logger
1
connection
Green 7 RS-232 RXD C (odd)
White 5 RS-232 TXD C (even)
Red 2 12 VDC 12V
Black 3, 1 Power and signal ground G
Clear NC Shield G
1
Assumes the sensor directly connects to the data logger.
6.2 Programming
Short Cut is the best source for up-to-date programming code for Campbell Scientific data
loggers. If your data acquisition requirements are simple, you can probably create and maintain a
data logger program exclusively with Short Cut. If your data acquisition needs are more complex,
the files that Short Cut creates are a great source for programming code to start a new program
or add to an existing custom program.
MetSENS-Series Compact Weather Sensors 11