Do you have a question about the Campbell ClimaVUE 50 and is the answer not in the manual?
Air Temperature Sensor Type | Thermistor |
---|---|
Air Temperature Resolution | 0.1°C |
Relative Humidity Sensor Type | Capacitive |
Wind Speed Sensor Type | Ultrasonic |
Wind Speed Resolution | 0.01 m/s |
Wind Direction Sensor Type | Ultrasonic |
Wind Direction Accuracy | ±3° |
Wind Direction Resolution | 1° |
Barometric Pressure Sensor Type | MEMS |
Barometric Pressure Accuracy | ±0.2 hPa (at 25°C) |
Barometric Pressure Resolution | 0.1 hPa |
Communication | SDI-12, RS-232, RS-485 |
Measurement Parameters | Air temperature, relative humidity, wind speed, wind direction, barometric pressure |
Relative Humidity Range | 0 to 100% RH |
Output | Digital |
Weight | 0.5 kg |
Relative Humidity Resolution | 0.1% |
Wind Speed Accuracy | ±0.3 m/s or ±3% of reading (whichever is greater) |
Operating Temperature | -40°C to +60°C |
Temperature Range | -40°C to +60°C |
Relative Humidity Accuracy | ±3% RH |
Details the function and operation of the ClimaVUE 50's drip counter rain gage.
Explains the pyranometer's role in measuring solar radiation and its cosine-corrected head.
Describes the ultrasonic anemometer for wind speed and direction measurement.
Details the RH sensor, its protective screen, and calculation of vapor pressure.
Explains the thermistor for temperature measurement and its correction method.
Covers the tilt sensor for leveling and its role in detecting orientation changes.
Locates the barometric pressure sensor and its measurement range.
Describes the lightning sensor detecting AM signal disruptions for strike distance.
Provides guidelines for locating the sensor away from obstructions for optimal readings.
Details the V-bolt mounting options and recommended poles/kits.
Lists the necessary tools for mounting the ClimaVUE 50 sensor.
Step-by-step instructions for physically mounting the ClimaVUE 50 to a pole or crossarm.
Instructions for installing the bird spike kit and its potential impact on data.
Explains the wire connections between the ClimaVUE 50 and the data logger.
Discusses using Short Cut for data logger programming.
Details the SDI12Recorder() instruction for sensor measurement.
Describes how the ClimaVUE 50 responds to SDI-12 commands for measurements.
Notes the sensor's limitations with frozen precipitation and ice buildup.
Discusses potential impacts of heavy rain and wind on sensor performance.
Provides equations for correcting barometric pressure to sea level.
Explains how the bird spike kit can affect solar radiation measurements.
Details correct installation of the bird spike kit to minimize data errors.
Outlines regular sensor maintenance and calibration procedures.
Provides solutions for common issues like NAN readings and no rain data.
Explains the structure and components of SDI-12 commands.
Details the 'aAb!' command for modifying a sensor's SDI-12 address.
Covers the 'aM!' command to initiate sensor measurements.
Explains how to use transparent mode for troubleshooting SDI-12 systems.
Provides steps to change an SDI-12 sensor's address using a terminal emulator.
Lists references for SDI-12 protocol and sensor support.