4. Type the correct SDI-12 Address (default is zero). Type the elevation of the site in the same
units as the Site elevation units. Default units are meters, which can be changed by clicking
on the Site elevation units box and selecting Feet.
5. Click on the Wiring tab to see how the sensor is to be wired to the data logger. If
measuring additional SDI-12 sensors and an unused control terminal is available on the
data logger, click on the control terminal (C) and change it to an unused control terminal,
then use the ClimaVUE 50 factory default address of 0 for the SDI-12 address. If an unused
control terminal is not available, type a new SDI-12 address in the SDI-12 address box, then
change the SDI-12 address in the ClimaVUE 50 (Change address command (aAb!) (p. 43)).
Click OK after wiring the sensor.
ClimaVUE 50 Compact Digital Weather Sensor 4