7.4 Sensor status code
NOTE:
For all factory repairs, customers must get an RMA number. Customers must also properly fill
out a “Declaration of Hazardous Material and Decontamination” form and comply with the
requirements specified in it. Refer to the Assistance page at the back of this manual for more
information.
Modbus and some SDI-12 commands output a four-digit status code that indicates whether the
sensor is working properly. The following table describes these codes.
Table 7-7: Status sensor code descriptions
Code Status Condition
0000 OK No fault conditions detected in measurement period
0001 WindMeasurementFault Wind sensor faulty
0010
Temperature
MeasurementFault
Temperature sensor faulty
0020 Dewpoint Fault
If temperature and humidity are reporting correctly, this
code indicates a main PCB fault.
0040 Humidity Fault Humidity sensor faulty
0080 Pressure Sensor Warning Pressure sensor reading not available/unit faulty
0100 Compass Fault Invalid heading due to compass fault