Table 7-1: MetSENS200 RS-485 registers
Starting register
number
Register
count
Data
format
Label Units Description
40001 2 FLOAT DIR °
Current, uncorrected
wind direction
40003 2 FLOAT SPEED m/s Current wind speed
40005 2 FLOAT COMPASSH °
Compass heading
of north mark
40007 2 FLOAT VOLT VDC Supply voltage
40009 2 FLOAT AVGDIR °
5 min. average wind
direction, updated every 30s
40011 2 FLOAT AVGSPEED m/s
5 min. average wind
speed, updated every 30s
40013 2 FLOAT GDIR ° Direction of wind gust
40015 2 FLOAT GSPEED m/s
3 s wind gust,
updated every 30s
40017 2 UNIT32 STATUS Sensor status code (p. 23)
Table 7-2: MetSENS300 RS-485 registers
Starting register
number
Register
count
Data
format
Label Units Description
40001 2 FLOAT PRESS hPa Barometric pressure
40003 2 FLOAT RH % Relative humidity
40005 2 FLOAT TEMP °C Air temperature
40007 2 FLOAT DEWPOINT °C Dewpoint
40009 2 FLOAT VOLT VDC Supply voltage
40011 2 UNIT32 STATUS Sensor status code (p. 23))
MetSENS-Series Compact Weather Sensors 16