6 | Cannon Fitzroy / Canterbury Inbuilt
INBUILT: FITZROY SPECIFICATIONS
Gas type Natural or Propane gas,
as indicated on data label
Gas consumption 26.0 MJ/hr
Energy output 5.98 kW / 21.45 MJ/hr
Energy star rating 4.05 stars
Heater type Gas space heater approved
to AS 4553:2008
Operating pressure
(at burner high setting)
Natural gas 0.75 kPa
Propane gas 2.65 kPa
Gas regulator Integral part of controller
Min. inlet pressure 1.13 kPa (NG)
2.75 kPa (Propane)
Fan 3 speed
Ignition Electronic direct spark
Power requirement 240 VAC 10 Amp
Power consumption 90 VA maximum
Minimum cavity
dimensions
Height 605 mm*
Width 700 mm*
Depth 405 mm*
Optional accessories •Glassfront
•Remotethermostat
•Spacerkit
•3sidedsurround
•4sidedsurround
•Consolekit
Overall dimensions Refer to FIG 3
*For installation into a non-combustible fireplace, ie:
masonry or brick
Please Note:
•Wheninstallingintoamockreplaceamock
fireplace installation kit must be used.
•Thedatalabelislocatedinthefanchamber.Access
by removing fascia.
Cannon Fitzroy Inbuilt
FIG 3 Front View and Side View
808 mm 50 mm 347 mm 8 mm
651 mm
600 mm