Cannon Fitzroy / Canterbury Inbuilt | 7
INBUILT: CANTERBURY SPECIFICATIONS
Cannon Canterbury Inbuilt
FIG 4 Front View and Side View
298 mm850 mm
Gas type Natural or Propane gas, as
indicated on data label
Gas consumption 26 MJ/hr input
Energy output 5.98 kW / 21.45 MJ/hr
Energy star rating 4.05 stars
Heater type Gas space heater approved to
AS4553:2008
Operating pressure
(at burner high setting)
Natural gas: 0.75 kPa
Propane gas 2.65 kPa
Gas regulator Integral part of controller
Min. inlet pressure 1.13 kPa (NG)
2.75 kPa (Propane)
Fan 3 speed
Ignition Electronic direct spark
Power requirement 240 VAC 10 Amp
Power consumption 90 VA maximum
Minimum cavity
dimensions
Height 605mm*
Width 700mm
Depth 385mm
Optional accessories •Safetymeshguard
•Remotethermostat
•Spacerkit
•3sidedsurround
•4sidedsurround
•Consolekit
Overall dimensions Refer to FIG 4
*For installation into a non-combustible fireplace, ie:
masonry or brick.
Please Note:
•Wheninstallingintoamockreplaceamock
fireplace installation kit must be used.
•Thedatalabelislocatedinthefanchamber.Access
by removing fascia.