20 Instruction manual C4061G/C4071G/C4091G Please keep this instruction manual for future reference
As the colours of the wires in the mains lead may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follows: Connect the Green & Yellow wire to
terminal marked ‘E’or
terminal
or
o
³ ³
³ ³
³
or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked “L” or coloured Red.
Connect the Blue wire to the terminal marked “N” or coloured Black.
BURNERS AND INJECTOR SPECIFICATIONS
³ ³
³ ³
³
G20 G30
Burner
Thermal
power
(kW)
Injector
1/100
(mm)
Thermal
power
kW
Injector
1/100
(mm)
Simmer
1.0
72-X
1.0
50
Semi rapid
1.75 97-Z 1.75 65
Rapid
3 115 3 85
Triple Ring
4.0
150
4.0
100