27
The control panel displays [ E ]:
The electronic system is defective.
Disconnect and reconnect the hob at the circuit breaker.
One or all cooking zone cut-off:
The safety system is activated.
You forgot to turn off the cooking zone for a long time.
One or more sensitive keys are covered.
The pan is empty and its bottom overheated.
The hob also has an automatic reduction of power level to prevent overheating
Continuous ventilation after turning off the hob:
This is not a failure; the fan continues to run to protect the electronic components.
The fan cooling stops automatically.
The automatic cooking system doesn’t start-up:
The cooking zone is still hot [ H ].
The highest power level is set [ 9 ].
The control panel displays [ ]:
Refer to the chapter “control panel locking”.
The control panel displays [ ] or [ ] or [ ]:
Refer to the chapter “Pan programs”.
The control panel displays [ II ] or [ ]:
Refer to the chapter “Pause”.
The control panel displays [ E8 ]:
The air inlet of the ventilator is obstructed, release it.
The control panel displays [ Er21 ]:
The hob is overheated, switch off, let it cool and then turn it on again.
The control panel displays [ Er31 ]:
The hob is not connected to the network. Check the connection and reconnect the hob.
The control panel displays [ Er47 ]:
The hob is not connected to the network. Check the connection and reconnect the hob.
The control panel displays [ Er61 ]:
The hob is not connected to the network. Check the connection and reconnect the hob.
The control panel displays [ Er62 ]:
Pan position not clear. Move the pan to another position.
If one of the symbols above persists, contact Caple Service.