EasyManua.ls Logo

Carel Heos - 2.2 Inverter Monofase 10 A

Carel Heos
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
ENG
Heos +0300078EN - rel. 1.6 - 23.11.2017
2.2 Inverter monofase 10A
For further details on the electrical and mechanical specifi cations, see
instruction sheet +0500076IE
1
2 3 4 5 6 7
J2
J3
J1
C
NO
-DC
+DC
PTC
24Vdc
Fig. 2.b
Description of the terminals:
Ref. Description
L, N
Single-phase power supply input
earth (*)
U, V, W
Motor output
earth (*)
-DC
DC bus output
+DC
J1-1 C
DC bus output
J1-2 NO
J2-3 0 V
RS485/ModBus®connectionJ2-4 Tx/Rx+
J2-5 Tx/Rx-
J3-6 PTC
PTC input (black connector)
J3-7 24 Vdc
E
PE
F (Led)
POWER (green) drive powered
RUN/FAULT (green/red) drive running / drive alarm
DATA (yellow) communication active
Tab. 2.c
(*) The earth connections inside the drive are electrically connected together and to PE.
Important: before carrying out any maintenance work,
disconnect the drive and the external control circuits from the power
supply by moving the main system switch to off . Once power has been
disconnected from the drive, wait at least 5 minutes before disconnecting
the electrical cables.
Coldplate with cooling adapter
The Coldplate with cooling adapter version (PSD10102BA) is provided
with four threaded holes M5 on the aluminum plate for fi xing.
Technical specifi cations
Operating temperature -20T60°C
Humidity <95% U.R. non-condensing
Pollution degree Max 2
Input voltage 200 - 240V ± 10%, 50 - 60Hz, 1~
Output voltage 0 - Input voltage
Output frequency 0 - 500 Hz
Maximum length 5 m
Switching frequency 4, 6, 8 kHz
Protection functions
Drive: short-circuit, overcurrent, ground fault,
overvoltage and undervoltage, overtemperature
Motor: overtemperature and overload
(150% rated
current for 1 minute)
System: short-circuit
Frequency resolution 0,1 Hz
Inputs
1 motor protector input: PTC temp. probe or
voltage-free contact max source current 10 mA,
max. length 25 m
Outputs
1 relay: Programmable output, voltage-free con-
tact: 240 Vac, 1 A
Serial data connection
RS485, Modbus® protocol, max. transmission speed
19200 bit/s.
24Vdc auxiliary power supply Double insulation, precision 10%, 50mA max
Maximum length 100m shielded cable
Index of protection IP00
Tab. 2.d
CE conformity:
2006/95/EC
EN 61800-5-1: Adjustable speed electrical power drive systems. Safety require-
ments. Electrical, thermal and energy.
2004/108/EC
EN 61800-3, ed.2.0.: Adjustable speed electrical power drive systems. EMC require-
ments and specifi c test methods.
EN61000-3-2: Electromagnetic compatibility (EMC) Part 3-2: Limits for harmonic
currents (equipment connected with input current > 16 A per phase).
EN61000-3-12: Electromagnetic compatibility (EMC) Part 3-12: Limits - Limits for harmo-
nic currents (equipment connected with input current > 16 A and <= 75 A per phase).
Rated values
The table below shows the rated input and output values, as well as the
specifi cations for sizing the cables (cross-section, maximum length) and
the fuses. The values refer to an operating temperature of 60 °C and a
switching frequency of 8 kHz, unless otherwise specifi ed.
PSD10102BA
Rated input current at 230V
17 A
Fuse or type B circuit breaker
25 A
Power cable cross-section
4 mm
2
Rated output current
10 A
Rated output power at 230V
3,8 kW
Max. total dissipation
270 W
Max. heatsink dissipation
150 W
Minimum motor cable cross-section
2,5 mm
2
Maximum motor cable length
5 m
Tab. 2.e
Assembly Dimensions
2
4
3
1
Key:
1 Coldplate cooling device (example)
2
Holes/screws for fastening the coldplate from rear of drive (4 x M5 holes, max.
14mm deep)
3 Holes/screws for fastening the coldplate from front of drive
4 Power+ plate
Note: the air-cooled heat sink is shown in grey in the dimensioned drawing.
197
177,6 40,9
209,5
7055,8
113,412,6 4
4,8
4,8
88
Ø5
138
102,8 39,3
6,9
65,7 7,3 7,5
6 87,1
78
M5

Related product manuals