Carel HUMISTEAM Specifications

General IconGeneral
Power SupplySingle or Three Phase (depending on model)
InstallationWall-mounted or floor-standing
Power consumptionDepends on model and capacity
Water connection3/4"
Max. water pressure10 bar
Operating temperature range5°C to 40°C
Dimensions (HxWxD)Varies by model
WeightVaries by model
Water SupplyPotable Water

Summary

Important Safety Warnings

Pre-Installation and Handling Precautions

Read and follow safety standards before installation or handling.

Models and Component Description

Humidifier Model Identification

Explains the 10-character model code structure and its meaning.

Component Identification and Diagrams

Detailed identification and diagrams of humidifier components.

Mounting and Installation

Receipt and Storage Procedures

Instructions for checking integrity and proper storage of the humidifier upon receipt.

Optimal Unit Positioning Guidelines

Guidance on selecting the best location for steam distribution and installation.

Wall Mounting and Fastening

Instructions for securely fastening the humidifier unit to the wall using screws.

Front Cover Removal and Reassembly

Step-by-step instructions for removing and reattaching the front cover of the unit.

Hydraulic Connections

Supply Water Quality Specifications

Defines the required characteristics and limits for supply water quality.

Drain Water Characteristics

Describes the properties of the drain water, including temperature and flow rate.

Water Supply and Drain Pipe Connections

Details on connecting the water supply and drain pipes to the unit.

Water Connection Diagrams

Illustrates the hydraulic connections for water supply and drain.

Hydraulic Connection Verification

Checks to ensure correct hydraulic connections are made.

Steam Distribution

Ventilated Steam Distributors

Using ventilated distributors for direct steam distribution into environments.

Steam Distribution in Cold Rooms

Humidifying cold rooms using specific distributors and operating within limits.

Duct Steam Distribution (Linear & OEM)

Using linear and OEM distributors for steam distribution in air ducts.

Linear Distributor Positioning in Air Ducts

Guidelines for positioning linear distributors within air ducts for optimal performance.

Steam Pipe Installation

Instructions for installing the steam pipe, including layout and connection.

Condensate Return Pipe Installation

Guidance on installing the condensate return pipe to prevent gurgling and efficiency loss.

Steam Pipe Installation Checks

Checks to ensure correct installation of the steam pipe and associated components.

Electrical Connections

Power Supply Voltage Specifications

Table detailing electrical data, power input, and steam production for various models.

Auxiliary Circuit Transformer Voltage Check

Procedure for checking the voltage of the multi-voltage auxiliary circuit transformer.

Main Control Board Overview

Details on the main control board, including terminal blocks and connections.

External Control Signals and Operation

Explains how to connect external signals for ON/OFF and proportional control.

Auxiliary Contacts and Connections

Information on alarm contacts, dehumidification contacts, and remote terminal connections.

Electrical Connection Verification

Checks to confirm correct electrical connections have been made as per diagrams.

Wiring Diagrams

Wiring Diagram: 1-5 kg/h Single-Phase (P Controller)

Provides the single-phase wiring diagram for 1-5 kg/h humidifiers with a P controller.

Wiring Diagram: 1-5 kg/h Single-Phase (H Controller)

Provides the single-phase wiring diagram for 1-5 kg/h humidifiers with an H controller.

Wiring Diagram: 3-15 kg/h Three-Phase (P Controller)

Provides the three-phase wiring diagram for 3-15 kg/h humidifiers with P controllers.

Wiring Diagram: 3-15 kg/h Three-Phase (H Controller)

Provides the three-phase wiring diagram for 3-15 kg/h humidifiers with H controllers.

Wiring Diagram: 25-65 kg/h Three-Phase (H Controller)

Provides the three-phase wiring diagram for 25-65 kg/h humidifiers with H controllers.

Wiring Diagram: 25-65 kg/h Three-Phase (P Controller)

Provides the three-phase wiring diagram for 25-65 kg/h humidifiers with P controllers.

Start-up, Control, and Shut-down

Start-up Safety Warnings

Essential warnings before starting the unit, including checking for leaks and ensuring electrical parts are dry.

Preliminary Checks Before Start-up

List of checks to perform before starting the humidifier to ensure proper installation and operation.

Unit Start-up Procedures

Detailed steps for starting the unit, including procedures for new and empty cylinders.

Humidifier Controller Overview

Description of the two types of electronic controllers (P and H) and their functionalities.

Unit Shut-down Procedure

Instructions for safely shutting down the humidifier for seasonal storage or maintenance.

Controller H Parameters

Parameter Grouping Levels

Parameters are grouped into three levels: Set Point, Control Parameters, and Configuration Parameters.

Ambient Humidity Set Point Adjustment

Procedure for reading and setting the ambient humidity set point using the control panel.

Control Parameters and Measurement Reading

Details on reading and setting control parameters and measurements related to humidification.

Configuration Parameter Setup

Instructions for setting configuration parameters for essential humidifier functions.

Recalling Factory Default Parameters

Procedure to restore the controller to its factory default settings.

Remote Control Operation

Remote Control Description

Overview of the remote control's features, buttons, and versions.

Programming via Remote Control

Instructions for accessing and modifying parameters using the remote control.

Exiting Programming Mode

How to exit the programming phase, with or without saving modifications.

Maintenance and Spare Parts

Cylinder Replacement Procedure

Detailed instructions and warnings for replacing the steam production cylinder.

Maintenance of Other Hydraulic Components

Guidance on maintaining components like electrovalves, manifolds, and tanks.

Component Replacement (Fuses)

Information on replacing fuses, including ratings and model compatibility.

Spare Parts Listing

Lists standard and special spare parts for single-phase and three-phase humidifiers.

Alarms, Troubleshooting, and Faults

Alarms on P Controllers

Describes alarm indications and behavior on P controllers.

Alarms on H Controllers

Describes alarm indications and behaviors on H controllers, including error codes.

Alarm and Signal Table

Comprehensive table detailing alarm codes, causes, solutions, and actions for P and H controllers.

Troubleshooting Table

Provides solutions for common humidifier problems and fault conditions.

Operating Principles and Control Functions

Operating Principle of Electrode Humidifiers

Explains the basic principle of humidity production using electrodes and water heating.

Control Principles and Modes

Details ON/OFF and proportional control principles for P and H controllers.

Additional Humidifier Functions

Describes functions like conductivity measurement, automatic draining, anti-foam, and dehumidification.

Technical Specifications

Dimensions and Weights

Provides physical dimensions and weight specifications for various humidifier models.

Remote Control Technical Specifications

Details the technical specifications of the infrared remote control unit.

Ventilated Steam Distributor Specs

Lists technical specifications for ventilated steam distributors used with different humidifier models.