58CV
Table
5
-
Air
Delivery
-
CFM
(With
Filter)*
(In.
W.C.)
External
.
CFM
Static
External
Static
Pressure
(ESP)
(IN.
W.C.)
Unit
Size
Operating
Mode
Airflow
Pressure
Setting
Range*
o1
|
02
|
03
|
04
|
05
|
06
1
tt
Low
Heat
735
(615)t
0—0.50
735
|
735
|
735
|
735
|
725
High
Heat
1180
(1060)t
0-1.0
1160
|
1165
|
1175
|
1180
|
1180
|
1180
|
1180
|
1180
|
1180
|
1175
tt
1—1/2—Ton
Cooling
525
0—0.50¢
515
|
500
|
500
|
490
|
485
tt
2—Ton
A/C
Cooling
700
0—0.50¢
690
|
680
|
675
|
680
|
675
2—1/2—Ton
A/C
Cooling
875
0-1.0+
875
|
875
|
875
|
870
|
865
|
855
|
850
|
835
|
825
|
820
3—Ton
A/C
Cooling
1050
0-1.0+
1050
|
1050
|
1050
|
1050
|
1050
|
1050
|
1045
|
1035
|
1020
|
1000
3—1/2—Ton
A/C
Cooling
1225
0-1.0
1220
|
1225
|
1225
|
1225
|
1225
|
1220
|
1205
|
1190
|
1185
|
1170
Maximum
1400
0-1.0
1395
|
1400
|
1400
|
1400
|
1395
|
1385
|
1370
|
1340
|
1300
|
1245
Low
Heat
985
(825)t
0-1.0
950
|
970
|
985
|
985
|
985
|
985
|
985
|
985
|
985
|
980
High
Heat
1210
(1090)t
0-1.0
1190
|
1205
|
1210
|
1210
|
1210
|
1210
|
1210
|
1210
|
1210
|
1200
tt
1—1/2—Ton
A/C
Cooling
525
0—0.50¢
525
|
520
|
525
|
495
|
475
tt
2—Ton
A/C
Cooling
700
0—0.50¢
680
|
680
|
680
|
675
|
670
2—1/2—Ton
A/C
Cooling
875
0-1.0+
815
|
845
|
845
|
855
|
850
|
850
|
845
|
835
|
820
|
805
3—Ton
A/C
Cooling
1050
0-1.0+
1005
|
1005
|
1015
|
1035
|
1040
|
1040
|
1035
|
1030
|
1025
|
1010
3—1/2—Ton
A/C
Cooling
1225
0-1.0
1190
|
1200
|
1200
|
1205
|
1205
|
1215
|
1205
|
1200
|
1185
|
1170
4—Ton
A/C
Cooling
1400
0-1.0
1350
|
1370
|
1390
|
1390
|
1400
|
1390
|
1380
|
1380
|
1360
|
1340
Maximum
1600
0-1.0
1595
|
1600
|
1600
|
1600
|
1595
|
1555
|
1505
|
1485
|
1430
|
1390
Low
Heat
1320
(1110)T
0-1.0
1275
|
1295
|
1315
|
1320
|
1320
|
1320
|
1320
|
1320
|
1320
|
1315
High
Heat
1475
(1330)T
0-1.0
1460
|
1465
|
1475
|
1475
|
1475
|
1475
|
1475
|
1475
|
1465
|
1465
tt
2—-Ton
A/C
Cooling
700
0-0.50¢
700 700 700 700 700
tt
2-1/2—Ton
A/C
Cooling
875
0-0.50¢
875 875 875 875 875
tt
3—Ton
A/C
Cooling
1050
0-0.50¢
1050
|
1050
|
1050
|
1050
|
1050
3-1/2—Ton
A/C
Cooling
1225
0-1.0$
1225
|
1225
|
1225
|
1225
|
1225
|
1225
|
1225
|
1225
|
1225
|
1225
4—-Ton
A/C
Cooling
1400
0-1.0$
1400
|
1400
|
1400
|
1400
|
1400
|
1400
|
1400
|
1400
|
1400
|
1400
5—Ton
A/C
Cooling
1750
0-1.0$
1750
|
1750
|
1750
|
1750
|
1750
|
1750
|
1750
|
1750
|
1740
|
1725
6—Ton
A/C
Cooling
2100
0-1.0
2100
|
2100
|
2100
|
2100
|
2090
|
2075
|
2055
|
2040
|
2005
|
1970
Maximum
2200
0-1.0
2200
|
2190
|
2190
|
2180
|
2155
|
2145
|
2125
|
2100
|
2080
|
2020
Maximum
Low
Heat
1700
(1430)T
0-1.0
1700
|
1700
|
1700
|
1700
|
1700
|
1695
|
1700
|
1695
|
1685 | 1670
High
Heat
1915
(1725)T
0-1.0
1900 |
1905
|
1915
|
1915
/
1915
|
1915
|
1915
/
1915
|
1915
|
1915
tT
2—-Ton
A/C
Cooling
700
0-0.50¢
700 700 700 700 665
tT
2-1/2—Ton
A/C
Cooling
875
0-0.50¢
870 870 865 865 865
tt
3—Ton
A/C
Cooling
1050
0-0.50¢
1010
|
1030
|
1050
|
1050
|
1050
3-1/2—Ton
A/C
Cooling
1225
0-1.0$
1155
|
1180
|
1200
|
1210
|
1220 | 1225
|
1225
|
1225
|
1225
|
1225
4—-Ton
A/C
Cooling
1400
0-1.0$
1395
|
1400
|
1400
|
1400
|
1400
|
1400
|
1400
|
1390
|
1375 | 1355
5—Ton
A/C
Cooling
1750
0-1.0$
1740
|
1750
|
1750
|
1750
|
1785
|
1740
|
1735
|
1730
|
1715
|
1700
6—Ton
A/C
Cooling
2100
0-1.0
2075
|
2085
|
2090
|
2100
|
2100
|
2100
|
2090
|
2080
|
2055
|
2025
2200
0-1.0
2180
|
2195
|
2200
|
2200
|
2200
|
2200
|
2185
|
2165
|
2140
|
2095
Low
Heat
1715
(1440)t
0-1.0
1715
|
1715
|
1715
|
1715
|
1715
|
1705
|
1710
|
1705
|
1705
|
1695
High
Heat
1970
(1775)T
0-1.0
1955 | 1965
|
1965
|
1970
|
1970
|
1970
|
1970
|
1970
|
1970
|
1960
tT
2—-Ton
A/C
Cooling
700
0-0.50¢
700 700 700 700 680
tT
2-1/2—Ton
A/C
Cooling
875
0-0.50¢
865 875 875 865 865
tt
3—Ton
A/C
Cooling
1050
0-0.50¢
1015
|
1020
|
1035
|
1045 | 1050
3-1/2—Ton
A/C
Cooling
1225
0-1.0$
1160
|
1185
|
1215
|
1225
|
1225 | 1225
|
1225
|
1225
|
1225
|
1225
4—-Ton
A/C
Cooling
1400
0-1.0$
1385
|
1400
|
1400
|
1400
|
1400
|
1400
|
1395
|
1395
|
1380 | 1360
5—Ton
A/C
Cooling
1750
0-1.0$
1745
|
1750
|
1750
|
1750
|
1745
|
1740
|
1745
|
1745
|
1740
|
1735
6—Ton
A/C
Cooling
2100
0-1.0
2055
|
2070
|
2080
|
2085
|
2095
|
2100
|
2100
|
2100
|
2090
|
2065
Maximum
2200
0-1.0
2175
|
2190
|
2200
|
2200
|
2200
|
2200
|
2200
|
2200
|
2180
|
2160
*Actual
external
static
pressure
(ESP)
can
be
determined
by
using
the
fan
laws
(CFM
2
proportional
to
ESP);
such
as,
a
system
with
1180
CFM
at
0.5
ESP
would
operate
at
cooling
airflow
of
1050
CFM
at
0.4
ESP
and
low—heating
airflow
of
735
CFM
at
0.19
ESP.
tComfort
airflow
values
are
shown
in
parenthesis.
Comfort
airflow
is
selected
when
the
low—heat
rise
adjustment
switch
(SW1—-3)
is
OFF
and
the
comfort/efficiency
switch
(SW1—-4)
is
ON.
+Ductwork
must
be
sized
for
high—heating
CFM
within
the
operational
range
of
ESP.
ttOperation
within
the
blank
areas
of
the
chart
is
not
recommended
because
high—heat
operation
will
be
above
1.0
ESP.
***All
airflow
on
110
size
furnace
are
5%
less
on
side
return
only
installations.
18