58CV
INTRODUCTION
The
Series
160
4-way
multipoise
Category
I
fan-assisted
furnace
is
CSA
(formerly
A.G.A.
and
C.G.A.)
design-certified. A
Category
I
fan-assisted
furnace
is
an
appliance
equipped
with
an
integral
mechanical
means
to
either
draw
or
force
products
of
combustion
through
the
combustion
chamber
and/or
heat
exchanger.
The
furnace
is
factory-shipped
for
use
with
natural
gas.
This
furnace
is
not
approved
for
installation
in
mobile
homes,
recreational
vehicles,
or
outdoors.
2
PEERREEERP
WNT
MAX80°F
/
27
C
reeeeeeerestuak
ips
2
phe
RETURN
AIR
MIN6O°F
/16C
crude
THE
A06745
Fig.
2
-
Return
Air
Temperature
This
furnace
is
designed
for
minimum
continuous
return-air
temperature
of
60°F
(15°C)
db
or
intermittent
operation
down
to
55°F
(13°C)db
such
as
when
used
with
a
night
setback
thermostat.
Return-air
temperature
must
not
exceed
80°F
(27°C)
db.
Failure
to
follow
these
return-air
temperature
limits
may
affect
reliability
of
heat
exchangers,
motors,
and
controls.
(See
Fig.
2.)
For
accessory
installation
details,
refer
to
the
applicable
instruction
literature.
NOTE:
Remove
all
shipping
brackets
and
materials
before
operating
the
furnace.
CODES
AND
STANDARDS
Follow
all
national
and
local
codes
and
standards
in
addition
to
these
instructions.
The
installation
must
comply
with
regulations
of
the
serving
gas
supplier,
local
building,
heating,
plumbing,
and
other
codes.
In
absence
of
local
codes,
the
installation
must
comply
with
the
national
codes
listed
below
and
all
authorities
having
jurisdiction.
In
the
United
States,
follow
all
codes
and
standards
for
the
following:
Safety
NFPA
54/ANSI
Z223.1-2009
and
the
Installation
Standards,
Warm
Air
Heating
and
Air
Conditioning Systems
ANSI/NFPA
9OB
.
General
Installation
Current
edition
of
the
NFGC
and
the
NFPA
90B.
For
copies,
contact
the
National
Fire
Protection
Association
Inc.,
Batterymarch
Park,
Quincy,
MA
02269;
(www.NFPA.org)
or
for
only
the
NFGC,
contact
the
American
Gas
Association,
400
N.
Capitol
Street,
N.W.,
Washington,
DC
20001
(www.AGA.org.)
.
Combustion
and
Ventilation
Air
Section
9.3
NFPA
54/ANSI
Z223.1-2009,
Air
for
Combustion
and
Ventilation
.
Duct
Systems
Air
Conditioning
Contractors
Association
(ACCA)
Manual
D,
Sheet
Metal
and
Air
Conditioning
Contractors
National
Association
(SMACNA),
or
American
Society
of
Heating,
Refrigeration,
and
Air
Conditioning
Engineers
(ASHRAE)
2001
Fundamentals
Handbook
Chapter
34
or
2000
HVAC
Systems
and
Equipment
Handbook
Chapters
9
and
16.
Acoustical
Lining
and
Fibrous
Glass
Duct
Current
edition
of
SMACNA
and
NFPA
90B
as
tested
by
UL
Standard
181
for
Class
I
Rigid
Air
Ducts
Gas
Piping
and
Gas
Pipe
Pressure
Testing
NFPA
54/ANSI
Z223.1-2009
;
chapters
5,
6,
and
7
and
National
Plumbing
Codes
.
Electrical
Connections
National
Electrical
Code
(NEC)
ANSI/NFPA70-2011
.
Venting
NFPA
54/ANSI
Z223.1-2009;
chapters
12
and
13.
ELECTROSTATIC
DISCHARGE
(ESD)
PRECAUTIONS
PROCEDURE
4&
CAUTION
FURNACE
RELIABILITY
HAZARD
Failure
to
follow
this
caution
may
result
in
unit
component
damage.
Electrostatic
discharge
can
affect
electronic
components.
Take
precautions
during
furnace
installation
and
servicing
to
protect
the
furnace
electronic
control.
Precautions
will
prevent
electrostatic
discharges
from
personnel
and
hand
tools
which
are
held
during
the
procedure.
These
precautions
will
help
to
avoid
exposing
the
control
to
electrostatic
discharge
by
putting
the
furnace,
the
control,
and
the
person
at
the
same
electrostatic
potential.
1.
Disconnect
all
power
to
the
furnace.
Multiple
disconnects
may
be
required.
DO
NOT
TOUCH
THE
CONTROL
OR
ANY
WIRE
CONNECTED
TO
THE
CONTROL
PRIOR
TO
DISCHARGING
YOUR
BODY’S
ELECTROSTATIC
CHARGE
TO
GROUND.
.
Firmly
touch
the
clean,
unpainted,
metal
surface
of
the
fur-
nace
chassis
which
is
close
to
the
control.
Tools
held
in
a
person’s
hand
during
grounding
will
be
satisfactorily
dis-
charged.
bo
3.
After
touching
the
chassis,
you
may
proceed
to
service
the
control
or
connecting
wires
as
long
as
you
do
nothing
to
recharge
your
body
with
static
electricity
(for
example;
DO
NOT
move
or
shuffle
your
feet,
do
not
touch
un-
grounded
objects,
etc.).

Related product manuals