33
HEAT PUMP HEATING PERFORMANCE CONTINUED
INDOOR AIR
OUTDOOR C O I L ENTERING AIR TEMPERATURES ° F (° C)
--- 3 ( --- 1 9 . 4 ) 7 (--- 13.9) 17 (--- 8.3) 27 (--- 2.8)
EDB
°F(°C)
ID SCFM
Capacity MBtuh
Tota l
System
KW†
ID SCFM
Capacity MBtuh
Tota l
System
KW†
ID SCFM
Capacity MBtuh
Tota l
System
KW†
ID SCFM
Capacity MBtuh
Tota l
System
KW†
Tota l Integ* Tota l Integ* Tota l Integ* To t a l Integ*
25VNA048A**30 Outdoor Section With FE4ANB006 Indoor Section --- Maximum
65
(18.3)
1800
31.83 29.29 3.91
1800
43.78 40.23 4.98
1800
52.18 47.57 5.41
1800
53.92 47.89 4.78
70
(21.1)
31.46 28.95 4.07 43.42 39.90 5.20 51.86 47.28 5.66 53.57 47.58 5.01
75
(23.9)
31.02 28.54 4.23 43.01 39.53 5.42 51.52 46.97 5.91 53.21 47.26 5.26
INDOOR AIR
OUTDOOR C O I L ENTERING AIR TEMPERATURES ° F (° C)
37 (2.8) 47 (8.3) 57 (13.9) 67 (19.4)
EDB
°F(°C)
ID SCFM
Capacity MBtuh
Tota l
System
KW†
ID SCFM
Capacity MBtuh
Tota l
System
KW†
ID SCFM
Capacity MBtuh
Tota l
System
KW†
ID SCFM
Capacity MBtuh
Tota l
System
KW†
Tota l Integ* Tota l Integ* Tota l Integ* To t a l Integ*
25VNA048A**30 Outdoor Section With FE4ANB006 Indoor Section --- Maximum
65
(18.3)
1800
51.12 46.52 3.76
1640
45.90 45.90 2.80
1640
52.16 52.16 2.89
1640
58.98 58.98 2.99
70
(21.1)
50.74 46.17 3.96 45.50 45.50 2.96 51.68 51.68 3.05 58.38 58.38 3.15
75
(23.9)
50.35 45.82 4.17 45.11 45.11 3.13 51.18 51.18 3.22 57.74 57.74 3.31
INDOOR AIR
OUTDOOR C O I L ENTERING AIR TEMPERATURES ° F (° C)
--- 3 ( --- 1 9 . 4 ) 7 (--- 13.9) 17 (--- 8.3) 27 (--- 2.8)
EDB
°F(°C)
ID SCFM
Capacity MBtuh
Tota l
System
KW†
ID SCFM
Capacity MBtuh
Tota l
System
KW†
ID SCFM
Capacity MBtuh
Tota l
System
KW†
ID SCFM
Capacity MBtuh
Tota l
System
KW†
Tota l Integ* Tota l Integ* Tota l Integ* To t a l Integ*
25VNA048A**30 Outdoor Section With FE4ANB006 Indoor Section --- Minimum
65
(18.3)
580
17.91 16.48 2.28
580
22.07 20.28 2.49
700
26.40 24.07 2.53
840
30.60 27.18 2.47
70
(21.1)
17.53 16.13 2.37 21.76 20.00 2.60 26.15 23.84 2.66 30.36 26.96 2.62
75
(23.9)
17.09 15.73 2.45 21.40 19.67 2.71 25.87 23.58 2.80 30.10 26.73 2.77
INDOOR AIR
OUTDOOR C O I L ENTERING AIR TEMPERATURES ° F (° C)
37 (2.8) 47 (8.3) 57 (13.9) 67 (19.4)
EDB
°F(°C)
ID SCFM
Capacity MBtuh
Tota l
System
KW†
ID SCFM
Capacity MBtuh
Tota l
System
KW†
ID SCFM
Capacity MBtuh
Tota l
System
KW†
ID SCFM
Capacity MBtuh
Tota l
System
KW†
Tota l Integ* Tota l Integ* Tota l Integ* To t a l Integ*
25VNA048A**30 Outdoor Section With FE4ANB006 Indoor Section --- Minimum
65
(18.3)
700
28.71 26.13 2.08
630
24.62 24.62 1.49
780
28.16 28.16 1.44
820
31.91 31.91 1.47
70
(21.1)
28.46 25.90 2.21 24.37 24.37 1.59 27.86 27.86 1.53 31.58 31.58 1.57
75
(23.9)
28.21 25.67 2.34 24.11 24.11 1.69 27.56 27.56 1.63 31.21 31.21 1.66
25VNA