19
2281.37
89.82[]
408.89
16.10[]
UNIT MOUNTING2769.30
109.03[]
812.70
32.00[]
UNIT MOUNTING2769.30
109.03[]
408.89
16.10[]
x
PS
PD
x
923.19
36.35[]
y
PD
PS
y
422.24
16.62[]
2073.54
81.64[]
7169.08
282.25[]
4164.26
163.95[]
3208.00
126.30[]
800.00
31.50[]
1963.74
77.31[]
1345.70
52.98[]
1297.44
51.08[]
PIPING ENTRANCE AREA
3208.06
126.30[]
1997.28
78.63[]
PD
z
PS
z
755.58
29.75[]
2236.08
88.03[]
931.93
36.69[]
200.00
7.87[]
100.00
3.94[]
y
CG
CG
x
960.40
37.81[]
400.00
15.75[]
240.00
9.45[]
246.36
9.70[]
336.50
13.25[]
39.89
1.57[]
UNIT MOUNTING
2156.30
84.89[]
200.00
7.87[]
200.00
7.87[]
2438.40
[96.00]
RIGGING HOLE
38.00
1.50[]
938.35
36.94[]
215.71
8.49[]
WEIGHT
CU/AL
lb/kg
MAX WEIGHT
CU/AL PUMP
lb/kg
WEIGHT
CU/CU
lb/kg
MAX WEIGHT
CU/CU PUMP
lb/kg
WEIGHT
MCHX
lb/kg
MAX WEIGHT
MCHX PUMP
lb/kg
CENTER OF GRAVITY PUMP SUCTION (PS) PUMP DISCHARGE (PD)
CGx
MM [INCH]
CGy
MM [INCH]
X
.25
Y
.25
Z
.25
X
.25
Y
.25
Z
.25
30RB-190,
360A,390A/B
12013
5461
13258
6014
13460
6118
14705
14705
11064
5019
12309
5582
3578
[140.87]
974
[38.35]
3002
[118.2]
381
[15.0]
297.2
[11.7]
2080.3
[81.9]
421.6
[16.6]
231.1
[9.1]
CIRCUIT B
COMPRESSORS
CIRCUIT A
COMPRESSORS
A
A
COIL SERVICE AREA
COIL SERVICE AREA
COOLER VENT
1/4" NTP
COOLER DRAIN
3/4" NPT
PUMP PACKAGE
LEAVING WATER
6" VICTAULIC
NO PUMP PACKAGE
ENTERING WATER
6" VICTAULIC
(SEE NOTE 4)
PUMP PACKAGE
ENTERING WATER
6" VICTAULIC
COOLER TUBE
SERVICE AREA
SERVICE AREA 1219.2[48.0] FROM EACH SIDE OF THE UNIT
SEE DETAIL B
VIEW A-A
SCALE 1:16
7/8" KNOCKOUT TO BE
USED FOR LOCATING
FIELD POWER WIRING
(DUAL AND SINGLE POINT)
POWER BOX 230V (CKT B)
POWER BOX
380V,460V,575V (CKT A,B)
DETAIL
B
SCALE 1:4
22.2 [.87]
MOUNTING HOLE
FIELD CONTROL WIRING
SCROLLING MARQUEE
DISPLAY
POWER BOX 230V ONLY (CKT A)
7/8" KNOCKOUT TO BE
USED FOR LOCATING
FIELD POWER WIRING
(DUAL POINT 230V ONLY)
(DUAL POWER NFD
CIRCUIT B 380,460,575V
ONLY)
FAN ELECTRICAL BOX
(FEB)
ALL VOLTAGES
AIR FLOW
BACnet COMMUNICATION
OPTION KNOCKOUT
FOR 1/2" CONDUIT
NOTES:
1. Unit must have clearances as follows:
Top — Do not restrict.
Sides and End — 6 (1.8 m) from solid surface.
2. All pumps have drains located at the bottom of volute for draining.
3. Temperature relief devices located on suction line, liquid line and
filter drier of each circuit and have
1
/
4
flare connection.
4. Units without a pump package have the same leaving water con-
nection, Y and Z dimensions (entering water), and Pump Dis-
charge X dimensions as units with a pump package.
5. Allow 8 ft (2.4 m) of service access on either side of unit for con-
denser coil removal.
6. Dimensions are in mm [inches].
a30-4589
MCHX — Microchannel Condenser Coil
Fig. 15 — 30RB190, 360A, 390A/B Air-Cooled Chiller Dimensions