EasyManua.ls Logo

Carrier 30RB060-390 - Page 20

Carrier 30RB060-390
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
2281.37
89.82[]
408.89
16.10[]
UNIT MOUNTING2769.30
109.03[]
812.70
32.00[]
UNIT MOUNTING2769.30
109.03[]
408.89
16.10[]
2073.54
81.64[]
7169.08
282.25[]
3208.00
126.30[]
800.00
31.50[]
1781.62
70.14[]
1773.54
69.82[]
755.58
29.75[]
2236.08
88.03[]
934.00
36.77[]
200.00
7.87[]
100.00
3.94[]
y
CG
CG
x
960.40
37.81[]
400.00
15.75[]
240.00
9.45[]
246.36
9.70[]
336.50
13.25[]
39.89
1.57[]
UNIT MOUNTING
2156.30
84.89[]
200.00
7.87[]
200.00
7.87[]
2X 343.58
13.53[]
343.81
13.54[]
553.81
21.80[]
5087.45
200.29[]
3344.54
131.67[]
1892.50
74.51[]
4459.04
175.55[]
601.22
23.67[]
PIPING ENETRANCE AREA
600.00
23.62[]
PIPING ENETRANCE AREA
600.00
23.62[]
PIPING ENETRANCE AREA
600.00
23.62[]
162.77
6.41[]
2X
503.37
19.82[]
2X 769.85
30.31[]
938.35
36.94[]
215.55
8.49[]
WEIGHT
MCHX
lb/kg
CENTER OF GRAVITY
CGx
MM [INCH]
CGy
MM [INCH]
30RB-190,
360A,390A/B
12850
5706
3566
[140.39]
979
[38.54]
CIRCUIT B
COMPRESSORS
SCROLLING MARQUEE
DISPLAY
CIRCUIT A
COMPRESSORS
A
A
HR CONDENSER
TUBE SERVICE AREA
COOLER VENT
1/4" NPT
COOLER DRAIN
3/4" NPT
COOLER
LEAVING WATER
6" VICTAULIC
COOLER
ENTERING WATER
6" VICTAULIC
CONDENSER DRAIN
3/8" NPT
AIR FLOW
FIELD CONTROL WIRING
FAN ELECTRICAL BOX
(FEB)
ALL VOLTAGES
POWER BOX 230V ONLY (CKT A)
7/8" KNOCKOUT TO BE
USED FOR LOCATING
FIELD POWER WIRING
(DUAL POINT 230V ONLY)
BACnet COMMUNICATION
OPTION KNOCKOUT
FOR 1/2" CONDUIT
COOLER TUBE
SERVICE AREA
SERVICE AREA 1219.2[48.0] FROM EACH SIDE OF THE UNIT
SEE DETAIL B
VIEW A-A
SCALE 1:32
7/8" KNOCKOUT TO BE
USED FOR LOCATING
FIELD POWER WIRING
(DUAL AND SINGLE POINT)
POWER BOX 230V (CKT B)
POWER BOX
380V,460V,575V (CKT A,B)
DETAIL B
SCALE 1:4
22.2 [.87]
MOUNTING HOLE
CONDENSER
ENTERING WATER
5.0" VICTAULIC
CONDENSER
LEAVING WATER
5.0" VICTAULIC
CONDENSER VENT
1/4" NPT
NOTES:
1. Unit must have clearances as follows:
Top — Do not restrict.
Sides and End — 6 (1.8 m) from solid surface.
2. Temperature relief devices located on suction line, liquid line and filter drier
of each circuit and have
1
/
4
flare connection.
3. Dimensions are in mm [inches].
4. Allow 8 ft (2.4 m) of service access on either side of unit for condenser coil
removal.
a30-4740
LEGEND
HR Heat Reclaim
MCHX Microchannel Condenser Coil
Fig. 16 — 30RB190 Air-Cooled Chiller with Heat Reclaim Option Dimensions

Related product manuals