20
Table 4 - Calculation of Indoor Piston No.
OUTDOOR UNIT ABOVE INDOOR
FT PISTON CHANGE
0-25
0
26-50
-3
51-75
-5
76-100
-7
101-125
-9
126-150
-10
OUTDOOR UNIT BELOW INDOOR
FT PISTON CHANGE
0-25
0
26-50
+4
Table 5 — Calculation of Outdoor Piston No.
OUTDOOR UNIT ABOVE INDOOR
FT PISTON CHANGE
0-50
0
51-75
+4
76-100
+6
101-125
+8
126-150
+10
OUTDOOR UNIT BELOW INDOOR
FT PISTON CHANGE
0-50 0
Table 6 — Common Piston Sizes
ACCURATER™ CHATLEFF ACCURATER™ CHATLEFF
— 32 65 65
—
33 67 67
35
35 — 68
—
36 70 70
—
37 — 71
38
38 73 73
—
39 — 74
40
40 76 76
—
41 78 78
42
42 80 80
—
43 — 81
—
45 82 82
46
— 84 84
—
47 86 86
49
49 88 88
51
51 — 89
52
52 90 90
— 53 — 92
55
55 93 93
57
57 96 96
59
59 98 98
61
61 101 101
—
62 104 104
63
63 109 —
Table 7—Liquid-Line Solenoid Kit Part Numbers
TYPE OF VALVE PART NO.
Single Flow
KAALS0101LLS
Bi-Flow
KHALS0101LLS