8
COOLING PERFORMANCE DATA
Model
COOLING OUTDOOR C ONDITIONS (DB)
Indoor
Conditions DB
Indoor
Conditions WB
77F(25C) 86F(30C) 95F(35C) 104F(40C) 113F(45C) 122F(50C)
09
(208 --- 230V)
69.8F(21C) 59F(15C)
TC 7.41 7.82 9.73 8.34 6.12 5.1
SC 6.64 6.69 8.18 7.37 4.36 3.74
Input 0.35 0.54 0.81 0.8 0.75 0.75
75.2F(24C) 62.6F(17C)
TC 7.76 9.16 9.89 8.62 6.92 5.83
SC 3.58 8.11 6.27 5.52 4.85 4.29
Input 0.35 0.54 0.81 0.8 0.75 0.75
80.6F(27C) 66.2F(19C)
TC 8.21 9.22 10.41 9.27 7.32 6
SC 7.39 5.88 8.22 7.79 5.11 4.37
Input 0.35 0.75 0.82 0.81 0.75 0.75
89.6F(32C) 73.4F(23C)
TC 8.41 9.72 11.59 10.22 8.82 7.51
SC 3.68 5.76 6.9 6.2 5.55 5
Input 0.36 0.56 0.83 0.82 0.76 0.77
12
(208 --- 230V)
69.8F(21C) 59F(15C)
TC 8.21 11.75 11.42 9 7.85 6.68
SC 7.06 9.05 8.68 7.38 6.42 5.58
Input 0.38 0.8 1.04 0.87 0.82 0.81
75.2F(24C) 62.6F(17C)
TC 8.42 11.84 12.01 9.35 8.32 7.34
SC 7.28 8.69 8.66 7.62 6.53 5.81
Input 0.57 0.94 1.25 1.27 0.98 0.94
80.6F(27C) 66.2F(19C)
TC 8.81 11.95 12.23 9.69 8.87 7.95
SC 7.49 8.32 8.63 7.85 6.64 6.04
Input 0.39 0.75 1.06 0.89 0.85 0.82
89.6F(32C) 73.4F(23C)
TC 9.01 12.15 12.43 9.89 9.07 8.15
SC 7.7 8.53 8.84 8.06 6.85 6.25
Input 0.4 0.97 1.3 1.34 0.92 0.85
LEGEND
DB - Dry Bulb
WB - Wet Bulb
TC - Total Net Cooling Capacity (1000 Btu/hour)
SC - S ensible Capacity (1000 Btu/hour)
Input - Total Power (kW)
HEATING PERFORMANCE DATA
Model
HEATING OUTDOOR CONDITIONS (DB)
Indoor
Conditions (DB)
53.6F(12C) 44.6F(7C) 39.2F(4C) 32F(0C) 24.8F(---4C) 19.4F(--- 7C) 17F(--- 8C) 5F(--- 15C) 0F(--- 17C) --- 4 F ( --- 2 0 C )
09
(208--- 230V)
59F(15C)
TC 11.18 11.08 10.89 10.65 9.87 9.11 8.27 6.71 6.21 5.80
Input 0.73 0.79 1.04 1.01 0.96 0.9 0.84 0.8 0.79 0.78
COP 4.49 4.11 3.07 3.09 3.01 2.97 2.88 2.46 2.30 2.18
64.4F(18C)
TC 11.06 10.82 10.65 10.54 9.63 8.84 8.01 5.46 5.02 4.60
Input 0.78 0.8 1.08 1.03 0.98 0.94 0.9 0.82 0.81 0.80
COP 4.15 3.96 2.89 3.00 2.88 2.76 2.61 1.95 1.82 1.69
69F(20.5C)
TC 10.84 10.55 10.48 10.32 9.43 8.55 7.95 4.29 4.11 4.02
Input 0.8 0.81 1.11 1.05 1 0.98 0.96 0.84 0.83 0.82
COP 3.97 3.82 2.77 2.88 2.76 2.56 2.43 1.50 1.45 1.44
71.6F(22C)
TC 10.62 10.32 10.21 10.11 9.23 8.41 7.89 4.11 3.86 3.60
Input 0.82 0.83 1.15 1.07 1.02 1.02 0.92 0.86 0.84 0.84
COP 3.79 3.64 2.60 2.77 2.65 2.42 2.51 1.40 1.35 1.26
12
(208--- 230V)
59F(15C)
TC 11.78 12.72 12.42 11.32 10.4 9.54 8.9 5.75 5.41 4.82
Input 0.79 1.01 1.05 1.1 1.02 1 0.98 0.83 0.8 0.78
COP 4.37 3.69 3.47 3.02 2.99 2.80 2.66 2.03 1.98 1.81
64.4F(18C)
TC 12.05 12.65 12.32 11.34 10.32 9.32 8.81 6.14 5.77 5.25
Input 0.83 1.37 1.4 1.26 1.22 1.27 1.01 0.91 0.86 0.82
COP 4.25 2.71 2.58 2.64 2.48 2.15 2.56 1.98 1.97 1.88
69F(20.5C)
TC 12.27 12.6 12.12 11.32 10.21 9.12 8.43 6.49 6.05 5.45
Input 0.83 1.1 1.12 1.19 1.19 1.25 1.03 0.98 0.92 0.86
COP 4.33 3.36 3.17 2.79 2.51 2.14 2.40 1.94 1.93 1.86
71.6F(22C)
TC 11.14 12.41 12.01 11.21 10.01 9.02 8.21 6.01 5.71 5.60
Input 0.85 1.15 1.16 1.21 1.23 1.31 1.05 1 0.98 0.94
COP 3.84 3.16 3.03 2.71 2.38 2.02 2.29 1.76 1.71 1.75
LEGEND
DB - Dry Bulb
TC - Total Net Heating Capacity (1000 Btu/hour)
Input - Total Power (kW)