4
 
Accessories
 
N/A = Not applicable in this application.
* Isolation relay required.
† For indicator light function, thermostat specified must be used and wired according to service alarm Installation Instructions.
‡ Consult low-ambient controller Installation Instructions for application.
** Start capacitor and relay required on 018-311.
 
ORDERING NUMBER DESCRIPTION
KSALA0101AAA
 
Low-Ambient Controller*
 
KAAFT0101AAA
 
Evaporator Freeze Thermostat‡
 
KHAIR0101AAA
 
Isolation Relay‡
 
N/A
 
Start Capacitor and Relay — Sizes 018 (301) and 024–060 (301, 311)
 
KSAHS0601AAA
 
Start Capacitor and Relay — Size 018 (311)
 
Standard
 
Crankcase Heater — Size 018 (311)
 
KAACH1201AAA
 
Crankcase Heater — Sizes 018 (301) and 024-060 (301, 311)
 
KSASH1801COP
 
Sound Blanket — Sizes 018 (301), 024
 
KSASH0601COP
 
Sound Blanket — Sizes 030–042
 
KSASH1701COP
 
Sound Blanket — Sizes 048, 060
 
KSASH0201TEC
 
Sound Blanket — Size 018 (311)
 
KHAOT0301FST
 
Outdoor Thermostat
 
KHAOT0201SEC
 
Secondary Outdoor Thermostat
 
KHASA0101AAA
 
Service Alarm†
 
KHAIC0101AAA
 
Furnace Interface Control (Optimizer II)
 
KHAIC0201AAA
 
Furnace Interface Control (Outdoor Thermostat/Lockout Relay)
 
KHATX0901HSO
 
Bi-flow TXV (Hard Shut-off) — Size 018**
 
KHATX1001HSO
 
Bi-flow TXV (Hard Shut-off) — Size 024
 
KHATX1101HSO
 
Bi-flow TXV (Hard Shut-off) — Sizes 030
 
KHATX1201HSO
 
Bi-flow TXV (Hard Shut-off) — Sizes 036–042
 
KHATX1301HSO
 
Bi-flow TXV (Hard Shut-off) — Sizes 048
 
KHATX1401HSO
 
Bi-flow TXV (Hard Shut-off) — Sizes 060
 
Standard
 
Low-Pressure Switch — Size 018 (311)
 
KHALP0101LPS
 
Low-Pressure Switch — Sizes 018 (301) and 024-060 (301, 311)
 
Standard
 
High-Pressure Switch — Sizes 018 (301) and 024–060 (301, 311)
 
KSAHI0201HPS
 
High-Pressure Switch — Size 018 (311)
 
P504-8083S
 
Refrigerant Filter Drier-Biflow (Sizes 018–036)
 
P504-8163S
 
Refrigerant Filter Drier-Biflow (Sizes 042–060)
 
KHALS0101LLS
 
Liquid Solenoid Valve
 
KSASF0101AAA
 
Support Feet — 4 in. (4)
 
KHASS0106MPK
 
Snow Rack — Sizes 018, 024
 
KHASS0206MPK
 
Snow Rack — Sizes 030 — 060
 
KAATD0101TDR
 
Time-Delay Relay
 
THERMOSTAT/SUBBASE
PKG DESCRIPTION
--HH--07AT-175
 
Thermostat, 2-Stage Heat, 1-Stage Cool, Auto/Manual Changeover — ˚F
 
--HH--07AT-165
 
Thermostat, 2-Stage Heat, 1-Stage Cool, Auto/Manual Changeover — ˚C
 
--HH--93AZ-195
 
Subbase for Manual Changeover Thermostat
 
--HH--93AZ-196
 
Subbase for Auto Changeover Thermostat
 
--HH--07ZE-001
 
Thermostat (1 Piece) 2-Stage Heat, 1-Stage Cool, Auto Changeover — ˚F
 
--HH--07ZE-004
 
Thermostat (1 Piece) 2-Stage Heat, 1-Stage Cool, Manual Changeover — ˚F
 
1F92-071 (RCD)
 
Thermostat (1 Piece) Night Setback, 2-Stage Heat, 1-Stage Cool — ˚F/˚C Option 
5-2 Day Programmable