7
PHYSICAL DATA
Outdoor Unit 38GXC(Q) 009 012 018 024
System Volatge 1 1 5 --- 1 --- 6 0 208/230---1 ---60
Control Voltage Low Voltage Pulse DC
Rated Cooling Capacity (Btuh) 8,600 12,000 17,000 21,000
Rated Heating Capacity (Btuh) 10,800 11,200 18,000 24,000
Operating Weight lb (kg) 88 (40) 114.4 (52) 141 (64)
Refrigerant Type R---410A
Metering Device Cap. Tube @ Outdoor Unit EXV @ Outdoor Unit
Charge lb (kg) 2.65 (1.2) 2.8 (1.27) 3.5 (1.6) 5.4 (2.5)
Compressor
Type Twin Rotary Inverter Driven
Model C--- 6RZ092H1AB C--- 6RVN93H0N C ---6RZ146H1A
Outdoor Fan
CFM 1060 1590
RPM 830 780/600
Diameter (in) … No. of Blades 15.7 … 3 18.1 … 3
W atts watts 30 60
Outdoor Coil
Face Area (sq.ft) 3.5 5.7 6.4
No. Rows 2
No. of Circuits
Fins per inch 18
Refrigerant Lines
Connection Type Flare
Liquid (Mix Phase) in OD 1/4” 3/8”
Vapor Line in OD 1/2” 5/8”
Maximum Length ft* 65 80 100
Max Lift (Fan Coil Above) ft 35 50 50
Max Drop (Fan Coil Below) ft 35 50 50
External Finish White
Indoor Unit 40GXC(Q) 009 012 018 024
System Voltage 115 V 208/230---1 ---60
Control Voltage Low Voltage Pulse DC
Electrical Connections Indoor Unit Powerd From Outdoor Unit
Rated Cooling Capacity (Btuh) 8,600 12,000 17,000 21,000
Rated Heating Capacity (Btuh) 10,800 11,200 18,000 24,000
Operating Weight lb (kg) 18.7 (8.5) 24.2 (11) 26.4 (12) 38.5 (17.5)
Refrigerant Type R---410A
Metering Device Cap. Tube @ Outdoor Unit EXV @ Outdoor Unit
Moisture Removal Rate (pints/hr) 2.5 6.3 8.4
Indoor Fan
RPM/CFM (Turbo) NA NA 1400/353 1360/471
RPM/CFM (High) 1200/290 1350/315 1260/318 1060/347
RPM/CFM (Medium) 1060/245 1200/268 1160/294 960/312
RPM/CFM (Low) 700/224 1100/245 1000/253 900/265
Motor Watts 13 20 20 35
Blower Quantity … Size in 1 … 3.8 x 23 1 … 3.6 x 24.3 1 … 3.8 x 31.4 2 … 3.8 x 16.7
Indoor Coil
Face Area (sq.ft) 2.4 2.4 2.9 2.6
No. Of Rows 2
Fins Per Inch 18 18 16 18
Number Of Circuits 2 3
Filters
Quantity 2
Controls Intergrated Microprocessor
Wireless Remote Standard
Modes Cool/Heat/Dry/Auto
Fan Mode High/Medium/Low/Auto
Emergency Mode Ye s
Defrost Method Demand Defrost
Diagnostics Ye s
Air Sweep Ye s
Soft Start Ye s
Rapid Cooling/Heating Ye s
Cold Blow Prevention Ye s
Sleep Mode Ye s
24 Hour Timer Ye s
Auto Restart Ye s
FreezeProtectionOnIndoorUnit Ye s
Refrigerant Lines
Connection Type Flare
Liquid (Mix Phase) in OD 1/4” 3/8”
Vapor Line in OD 1/2” 5/8”
Maximum Length ft* 65 80 100
Max Lift (Fan Coil Above) ft 35 50 50
Max Drop (Fan Coil Below) ft 35 50 50
Condensate Drain
Size in ID = 1/2” OD = 5/8”
External Finish White
* For Heat Pump models
** Refer to Long Line Application section on page 9
38/40GXC(Q)