Maintenance and service
ATTENTION:
Before performing any service or
maintenance operations, turn OFF the
main power switch.
In order to obtain maximum performance,
special attention should be paid to the
following points:
Inspect and clean the outdoor unit,
especially the heat exchanger coil.
Ensure that all rubber and insulating
joints are in good condition.
Check and clean condenser drain pan of
the indoor unit; the same check must be
made for the heat pump outdoor units.
Check tightness of electric connections.
Clean or replace the air filter of the indoor
unit.
Air filter.
Manutenzione e cura
ATTENZIONE:
Prima di iniziare qualunque operazione
di pulizia o di manutenzione togliere
l’alimentazione elettrica.
Per ottenere ottime prestazioni, si consiglia
di prestare particolare attenzione ai
seguenti punti:
Ispezionare e pulire l'unità esterna ed in
particolare la batteria di scambio
termico.
Assicurarsi che i giunti in gomma e
isolanti siano in buone condizioni.
pulire e liberare da eventuali ostruzioni la
bacinella e lo scarico della condensa
dell'unità interna; eseguire gli stessi
controlli sulle unità esterne a pompa di
calore.
controllare il serraggio dei contatti
elettrici.
pulire o sostituire il filtro dell'aria dell'uni-
tà interna.
Filtro aria.
Troubleshooting chart
Alarm code
Code Description
2 Indoor unit air sensor
3 Indoor unit coil sensor
4 Outdoor unit coil sensor
6 Outdoor unit in alarm mode
7 Condensation pump /
Condensation level
Example:
Outdoor unit coil sensor not connected or
not operating.
The alarm code (3) is deduced from the
number of times the green LED flashes, at
intervals of 5 seconds, blocking unit
operation.
A series of possible faults is related below,
as well as the probable causes and
suggested solutions.
However, in the event of a unit malfunction,
it is advisable to disconnect the power
supply and ascertain the cause.
Symptoms / Cause / R
EMEDY
Unit does not start
No power supply: C
HECK
Main switch open: CLOSE SWITCH
Current wires cut: REPAIR OR REPLACE
Fuses blown:
R
EPLACE AND CHECK CONSUMPTIONS
Protector tripped: RESET AS DESCRIBED
Thermostat wrongly adjusted:
S
ELECT A MORE SUITABLE TEMPERATURE
Ricerca inconvenienti
Codice di allarme
Codice Descrizione
2 Sensore aria unità interna
3 Sensore batteria unità interna
4 Sensore batteria unità esterna
6 Unità esterna in allarme
7 Pompa condensa / livello
condensa
Esempio:
Sensore batteria unità interna non collega-
ta o non funzionante.
Il codice di allarme (3) si deduce dalle volte
che il led verde lampeggia, ad intervalli di 5
secondi, bloccando il funzionamento
dell'unità.
Di seguito sono nominati alcuni inconve-
nienti possibili, con la causa probabile e la
soluzione suggerita.
In ogni caso è consigliabile togliere
l’alimentazione e accertare la causa.
Anomalia / Causa / R
IMEDIO
L'unità non funziona
Mancanza di alimentazione elettrica: V
ERIFICARE
Interruttore principale aperto: C
HIUDERE
L
INTERRUTTORE
Cavi della corrente tagliati: R
IPARARE
O
SOSTITUIRE
Fusibili bruciati:
S
OSTITUIRE
E
VERIFICARE
GLI
ASSORBIMENTI
Una protezione è intervenuta: R
ISTABILIRE
COME
DESCRITTO
Termostato regolato erroneamente
S
ELEZIONARE
UNA
TEMPERATURA
PIÙ
ADEGUATA