Product Data
40QNC / 38HDF
40QNQ / 38QRF
High---W all Duct F ree Split System
Sizes 018 to 036
The ideal compliment to your ducted system when it is impractical
or prohibitively expensive to use ductwork.
INDUSTRY LEADING
FEATURES / BENEFITS
AN INEXPENSIVE AND CREATIVE
SOLUTION TO DESIGN PROBLEMS.
The 38HDF(QRF) / 40QNC (QNQ) series duct--free split systems
are a matched combination of an outdoor condensing unit and an
indoor fan coil unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the wall, near the ceiling. This
selection of fan coils permits inexpensive and creative solutions to
design problems such as:
S Add--ons to current space (an office or family room
addition)
S Special space requirements
S When changes in the load cannot be handled by the
existing system.
S When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork.
S Historical renovations or any application where
preserving the look of the original structure is essential.
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors. Advanced system
components incorporate innovative technology to provide reliable
cooling performance at low sound levels.

Other manuals for Carrier 40QNC

Questions and Answers

  • S
    Susan TylerJul 28, 2025
    How to troubleshoot Carrier Air Conditioner compressor and fan not starting?
    • S
      Shane NelsonJul 28, 2025
      If the compressor and fan of your Carrier Air Conditioner's outdoor unit won't start, first, ensure the unit is energized by checking the main power connection. Then, verify that the main switch is in the ON position and that the main switch fuses are not blown; replace them if necessary. If the compressor cycling protection is active, wait for 3 minutes. Also, check that the main power voltage is correct and that all electrical connections are secure and properly connected.
  • N
    Nancy JonesAug 1, 2025
    Why does my Carrier Air Conditioner compressor keep running?
    • K
      Karen HernandezAug 1, 2025
      If the compressor in your Carrier Air Conditioner runs continuously, it could be due to several reasons. First, check if the indoor temperature setting is too low or too high. A faulty outdoor unit fan could also be the cause, requiring replacement. Additionally, obstructions at the air intake or dirty indoor unit filters can lead to this issue; remove any obstructions and clean the filter. In some cases, the unit may be too small for the application requirements, and you should contact a qualified service technician for a system evaluation. Air or other non-condensable gasses in the circuit can also cause this issue, requiring you to drain refrigerant, evacuate and recharge the system.
  • C
    Caitlin BakerAug 6, 2025
    What to do if Carrier 40QNC Air Conditioner discharge pressure is too high?
    • S
      Sandra BentleyAug 6, 2025
      If the discharge pressure of your Carrier Air Conditioner is too high, it could be due to a dirty or obstructed outdoor coil; clean or remove any obstructions. A faulty condenser fan can also cause this issue, requiring replacement. Additionally, an incorrect indoor temperature setting could be the problem, so check and adjust it as needed. Air or other non-condensable gasses in the circuit might also be the cause, necessitating draining the refrigerant, evacuating, and recharging the system.
  • C
    Casey HoganAug 10, 2025
    Why is the suction pressure too low on my Carrier Air Conditioner?
    • M
      Michael SmithAug 10, 2025
      If the suction pressure of your Carrier Air Conditioner is too low, first check the indoor temperature setting to ensure it is appropriately adjusted. The issue might also stem from an evaporator coil covered with ice, indicating insufficient air circulation that needs checking and repair. Additionally, a clogged expansion device or suction line could be responsible, requiring inspection and repair. Inspect the electrical parts to ensure the outdoor fan stops during defrost periods.
  • S
    smartinAug 14, 2025
    What causes low discharge pressure in Carrier 40QNC?
    • D
      dcunninghamAug 14, 2025
      If the discharge pressure of your Carrier Air Conditioner is too low, check the indoor temperature setting. It might be set too high or too low. Also, make sure the outdoor coil isn't dirty or obstructed; clean it if necessary. A dirty indoor unit air filter can also cause this issue; clean the filter to resolve it.
  • R
    Ricardo WilliamsAug 23, 2025
    What causes high suction pressure in Carrier 40QNC?
    • V
      vernonturnerAug 23, 2025
      If the suction pressure of your Carrier Air Conditioner is too high, first check the indoor temperature setting. It might be set too high or too low. A faulty reversing valve or an internal leak could also be the cause, requiring replacement of the reversing valve.
  • K
    Karina ChavezNov 18, 2025
    Why does my Carrier 40QNC Air Conditioner compressor stop due to over-temperature?
    • A
      Anna MorenoNov 18, 2025
      If your Carrier Air Conditioner's compressor stops due to over-temperature, it could be due to several reasons. The compressor might be burnt out, seized, or the protection device may be activated; check for the cause and replace the compressor if needed. An incorrect refrigerant charge (either excessive or low), or the presence of air or other non-condensable gasses in the circuit can also cause this; in such cases, drain the refrigerant, evacuate, and recharge the system. Ensure that you do not vent refrigerant to the atmosphere and use refrigerant recovery equipment. Also, check if the main voltage is too high or too low and adjust it if necessary. Inspect the condenser coil for obstructions and remove them. If the outdoor fan is off, determine the cause and resume operation or repair i...

Summary

Industry Leading Features & Benefits

Key Advantages and Solutions

Highlights industry-leading features and creative design solutions.

Operational Benefits

Covers sound levels, security, installation, servicing, reliability, and comfort.

Physical Data

Outdoor Unit Physical Data

Technical specifications for outdoor units (38HDF/38QRF).

Application Data

Unit Selection and Mounting

Guidance on unit selection, indoor/outdoor mounting, and operating conditions.

Refrigerant Lines and Controls

Carrier 40QNC Specifications

General IconGeneral
BrandCarrier
Model40QNC
CategoryAir Conditioner
LanguageEnglish