EasyManua.ls Logo

Carrier 40QNH - User Manual

Carrier 40QNH
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation, Start-Up
and Service Instructions
CONTENTS
Page
SAFETY CONSIDERATIONS
.....................1
GENERAL ....................................1,2
INSTALLATION ..............................2-14
Step 1 Complete Pre-Installation Checks .......2
UNPACK UNIT
INSPECT SHIPMENT
Step 2 Select Location
.......................2
Step 3 Mount Mounting Bracket on Wall ........5
Step 4 Connect Refrigerant Piping .............5
Step 5 Connect Condensate Drain Line ........11
Step 6 Make Electrical Connections ...........12
Step 7 Make Connections to Outdoor Unit .....13
COOLING-ONLY SYSTEMS
HEAT PUMP SYSTEMS
Step 8 Install Fan Coil Unit Onto Mounting
Bracket
....................................13
START-UP .................................14-17
40QN Control System .........................14
After Extended Shutdowns .....................15
Seasonal Changeovers ........................15
To Turn The Unit On and Off ...................15
Adjusting Airflow .............................15
Operating Mode Memory .......................15
Automatic Operation (Auto) Mode ...............15
Operating Fault Diagnosis .....................15
Microprocessor Control Operation ..............15
CLEANING AND MAINTENANCE ...............18,19
Lubrication ..................................18
To Install or Replace Remote Controller
Batteries ...................................18
To Set the Current Time .......................19
To Remove and Clean or Replace Air Filters ......19
TO REMOVE AIR FILTERS
TO CLEAN OR REPLACE FILTERS
To Clean Indoor Unit Front Panel
...............19
To Clean Indoor Coil ..........................19
To Clean Outdoor Coil (Outdoor Unit) ...........19
Cleaning Condensate Drains ...................19
SERVICE ....................................20
Diagnostic Codes .............................20
System Tests ................................20
THERMISTOR TESTS
THERMISTORS
COMPRESSOR FAILURE
REVERSING VALVE FAILURE (38BK Only)
System Safeties and Interlocks
.................20
INDOOR FAN FAILURE
COMPRESSOR SHORT-CYCLING PROTECTION
INDOOR COIL FREEZE PROTECTION
(Cooling or Dehumidification Mode Only)
INDOOR COIL HIGH-TEMPERATURE
PROTECTION (Heat Pump Systems Only)
TROUBLESHOOTING
........................20-26
START-UP CHECKLIST ..................CL-1,CL-2
SAFETY CONSIDERATIONS
Installing and servicing air-conditioning equipment can be
hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should
install or service air-conditioning equipment.
Untrained personnel can perform basic maintenance, such
as cleaning and replacing filters. All other operations should
be performed by trained service personnel. When working
on air conditioning equipment, observe precautions in lit-
erature and on tags and labels attached to unit.
Follow all safety codes. Wear safety glasses and work gloves.
Use quenching cloth for brazing operations. Have fire ex-
tinguisher available. Read these instructions thoroughly. Con-
sult local building codes and National Electrical Code (NEC)
for special installation requirements.
Before installing or servicing system, always turn off
main power to system. There may be more than one dis-
connect switch. Turn off indoor fan coil power if ap-
plicable. Electrical shock can cause personal injury.
GENERAL
The Carrier 40QNH heat pump high wall fan coil units
(Fig. 1) come with supplemental electric heat. If your ap-
plication requires heating, heat pump units must be used, both
outdoors and indoors. See Table 1 for recommended system
combinations.
Fig.1—Typical 40QNH High Wall Fan Coil Unit
40QNB,QNH
018,024
High Wall Fan Coil Units
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1 4
Tab 3e 2f
PC 111 Catalog No. 534-003 Printed in U.S.A. Form 40QN-4SI Pg 1 5-99 Replaces: 40QN-1SI

Questions and Answers:

Carrier 40QNH Specifications

General IconGeneral
BrandCarrier
Model40QNH
CategoryComputer Hardware
LanguageEnglish

Summary

Safety Considerations

General Safety Precautions

General safety advice and warnings for installation and servicing of air-conditioning equipment.

WARNING: Electrical Shock Hazard

Warning about turning off all power to the system to prevent electrical shock.

Installation Procedures

Pre-Installation Checks

Procedures for checking the unit before installation, including unpacking and inspection.

Step 1 - Complete Pre-Installation Checks

Detailed steps for unpacking and inspecting the unit upon receipt.

Start-Up Procedures

Preliminary Checks

Essential checks before starting the system, including drainage and wiring.

Emergency and Test Mode Operation

Using the unit when the remote control is unavailable or for testing purposes.

Cleaning and Maintenance

General Cleaning Precautions

Safety warnings before performing maintenance, including power disconnection.

Air Filter Maintenance

How to remove, clean, or replace air filters for optimal performance.

Service and Diagnostics

System Tests and Thermistor Checks

Performing system tests and checking thermistor functionality.

Compressor and Reversing Valve Failure

Identifying compressor and reversing valve failures in the system.

Diagnostic Codes and LED Indicators

Detailed explanation of diagnostic codes and LED flashes for fault identification.

System Tests Overview

How the system performs continuous tests and its response to faults.

Thermistor Functionality

How thermistors are tested and their importance for unit operation.

Compressor Failure Detection

How the system detects compressor failures in cooling or heating modes.

Reversing Valve Failure Detection

How reversing valve failures are detected in heat pump systems.

System Safeties and Interlocks

Understanding system safeties like fan failure and freeze protection.

Troubleshooting Guide

Unit Operation Issues

Steps to troubleshoot unit not operating or stopping unexpectedly.

Cooling and Heating Performance Issues

Steps to troubleshoot insufficient cooling or heating performance.

Schematics and Diagrams

40 QNH Unit with 38 BK Outdoor Wiring

Detailed wiring diagram for a 40QNH unit with a 38BK outdoor heat pump unit.

40 QNB Unit with 38 HDC Outdoor Wiring

Wiring diagram for a 40QNB unit with a 38HDC cooling-only outdoor unit.

Start-Up Checklist Details

Related product manuals