94
42DA,DC,DE AND DF OPTIONAL COIL CONNECTION LOCATION SIZES 06–20
a42-3996
NOTES:
1. Refer to pages 92 and 93 for coil inlet and outlet knockout locations on DE and DF units.
2. Cooling coil is first in the airstream.
3. Split coil connections shown are for 4-pipe combination chilled water/hot water coils only,
UNIT CFM
COIL CONNECTION DIMENSIONS (in.)
3-Row 4-Row 6-Row
ACFGACFGACFG
Right
Hand
600-800
1000-2000
3
7
/
8
3
7
/
8
6
6
7
5
/
16
9
13
/
16
7
5
/
16
9
13
/
16
2
13
/
16
6
1
/
16
4
13
/
16
10
7
/
16
1
3
/
4
7
1
/
8
4
13
/
16
10
7
/
16
Left
Hand
600-800
1000-2000
3
7
/
8
3
7
/
8
6
6
7
15
/
16
5
7
/
16
7
5
/
16
10
7
/
16
2
13
/
16
6
1
/
16
5
7
/
16
9
13
/
16
1
3
/
4
7
1
/
8
5
7
/
16
13
/
16
UNIT CFM
COIL CONNECTION DIMENSIONS (in.)
3 and 1 Split Coil 3 and 2 Split Coil
ABCDEFGABCDEFG
Right
Hand
600-800
1000-2000
2
13
/
16
2
13
/
16
3
7
/
8
3
7
/
8
6
1
/
16
6
1
/
16
1
1
/
16
1
1
/
16
7
5
/
16
4
13
/
16
7
5
/
16
9
13
/
16
13
9
/
16
13
9
/
16
2
1
/
4
2
1
/
4
3
7
/
8
3
7
/
8
6
1
/
16
6
1
/
16
3
/
4
3
/
4
7
5
/
16
4
13
/
16
7
5
/
16
9
13
/
16
13
1
/
4
13
1
/
4
Left
Hand
600-800
1000-2000
2
13
/
16
2
13
/
16
3
7
/
8
3
7
/
8
6
1
/
16
6
1
/
16
7
/
16
7
/
16
7
15
/
16
5
7
/
16
7
15
/
16
10
7
/
16
12
15
/
16
12
15
/
16
2
1
/
4
2
1
/
4
3
7
/
8
3
7
/
8
6
1
/
16
6
1
/
16
3
/
4
3
/
4
7
15
/
16
5
7
/
16
7
15
/
16
10
7
/
16
13
1
/
4
13
1
/
4
UNIT CFM
COIL CONNECTION DIMENSIONS (in.)
4 and 1 Split Coil 4 and 2 Split Coil
ABCDEFGABCDEFG
Right
Hand
600-2000
3
/
4
2
13
/
16
6
1
/
16
7
/
16
4
13
/
16
10
7
/
16
12
15
/
16
2
1
/
4
3
7
/
8
7
1
/
8
3
/
4
4
13
/
16
10
7
/
16
13
1
/
4
Left
Hand
600-2000
3
/
4
2
13
/
16
6
1
/
16
1
1
/
16
5
7
/
16
9
13
/
16
13
9
/
16
2
1
/
4
3
7
/
8
7
1
/
8
3
/
4
5
7
/
16
9
13
/
16
13
1
/
4
UNIT CFM
COIL CONNECTION DIMENSIONS (in.)
6 and 1 Split Coil
ABCDEFG
Right
Hand
600-800
1000-2000
1
3
/
4
2
7
/
8
8
1
/
4
3
/
8
4
3
/
4
10
3
/
8
13
1
/
4
Left
Hand
600-800
1000-2000
1
3
/
4
2
7
/
8
8
1
/
4
3
/
8
4
3
/
4
10
3
/
8
13
1
/
4
NOTE: Does not apply to connection size when optional valve
packages are used.
COIL CONNECTIONS SIZES (OD COPPER SWEAT) (in.)
cfm 1-2 Row 3 Row 4 Row 5 Row 6 Row 8 Row
600
5
/
8
5
/
8
7
/
8
7
/
8
7
/
8
1
1
/
8
800
5
/
8
5
/
8
7
/
8
7
/
8
7
/
8
1
1
/
8
1000
5
/
8
7
/
8
7
/
8
7
/
8
7
/
8
1
1
/
8
1200
5
/
8
7
/
8
7
/
8
7
/
8
7
/
8
1
1
/
8
1400
5
/
8
7
/
8
7
/
8
1
1
/
8
1
1
/
8
1
5
/
8
1600
5
/
8
7
/
8
1
1
/
8
1
1
/
8
1
1
/
8
1
5
/
8
1800
5
/
8
7
/
8
1
1
/
8
1
1
/
8
1
1
/
8
1
5
/
8
2000
5
/
8
7
/
8
1
1
/
8
1
1
/
8
1
1
/
8
1
5
/
8
Accessory dimensions