EasyManua.ls Logo

Carrier 42LUVH045N - Electronic Functions and Operation; Technical Abbreviations; Indoor Unit Display Icons; Protection Mechanisms

Carrier 42LUVH045N
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
8.Electronic function
8.1 Abbreviation
T1: Indoor ambient temperature
T2: Pipe temperature of indoor heat exchanger
T3: Pipe temperature of outdoor heat exchanger
T4: Outdoor ambient temperature
8.2 Display function
8.2.1 Icon explanation on indoor display board.
42VHC109713G 42VHC112713G 42VHC118713G
Auto indicator
This indicator illuminates when the air conditioner is in AUTO operation.
Timer indicator
This indicator illuminates when TIMER is set ON/OFF.
PRE.-DEF. Indicator
This indicator illuminates when the air conditioner starts defrosting automatically or when the warm air control
feature is activated in heating mode.
TEMPERATURE indicator
Usually it displays the temperature settings. When change the setting temperature, this indicator
begins to flash, and stops 20 seconds later.
It displays the room temperature when the air conditioner is in FAN only operation, and the range of that is
0~50. When the unit stops operation, it returns to original factory settings.
Displays the malfunction code or protection code.
Frequency indicator
This indicator appears only when the compressor is in operation and indicates the current
operating frequency.
8.2.2 LED display control function.
Pressing LED display button on remote controller will turn off all displays on indoor unit, while pressing
once again, all displays will resume.
8.3 Protection
8.3.1 Three Minutes Delay at restart for compressor.
8.3.2 Temperature protection of compressor top.
8.3.3 If the temperature of compressor top is too high(higher than 115 and the Over-load Protector is cut,
the units stop. When the Over-load Protector restore and close(lower than 100), the compressor will
restart( in this case the compressor is restricted by Three Minutes Delay protection).
8.3.4 Temperature protection of compressor exhaust.

Related product manuals