39
Model: YDK50-6C
Measure the resistance value of each winding by using the multi-meter.
Indoor Fan Motor
Model: RPG20D
Measure the resistance value of each winding by using the multi-meter.
Model: RPG28D
Measure the resistance value of each winding by using the multi-meter.
9.3.4 Step Motor (Model: MP2835 MP2423B).
Measure the resistance value of each winding by using the multi-meter.
Position
Resistance Value
Black - Red
114Ω (20)
Blue - Red
188Ω (20)
Yellow - Blue
172Ω (20)
Position
Resistance Value
Black - Red
400Ω±8% (20)
White - Black
383Ω±8% (20)
Position
Resistance Value
Black - Red
260Ω±8% (20)
White - Black
385Ω±8% (20)
Position
Resistance Value
Blue - Red
200Ω±7% (25)
Pink - Orange
Pink - Yellow
Yellow - Red