10-5. Test Operation
10-5-1. Gas Leak Test
Check the flare nut connections for gas leaks with
a gas leak detector and/or soapy water.
10-5-2. Test Operation
To test the system, press and hold RESET button for
10 sec. (There will be one short beep.)
10-5-3. Auto Restart Setting
This product is designed so that, after a power
failure, it can restart automatically in the same
operating mode as before the power failure.
Information
The product was shipped with Auto Restart
function in the OFF position.
Turn it ON as required.
How to Set the Auto Restart
Press and hold the RESET button for about 3
seconds. After 3 seconds, three short electric
beeps will be heard to inform you that the Auto
Restart has been selected.
To cancel the Auto Restart, follow the steps
described in the section Auto Restart Function on
Owners Manual.
10-5-4. Remote Controller A or B Selection
Setting
FILE NO. SVM-07013
Fig. 10-5-1
RESET
RESET button
Fig. 10-5-1
Fig. 10-5-2
When two indoor units ae installed in seperated rooms,
there is no need to change the selector switch.
<Remote control selector switch>
When two indoor units are installed in the same room or
adjacent two rooms, if operating a unit, two units may
receive the remote control signal simultaneously and
operate. In this case, the operation can be preserved
by setting either one indoor unit or remote control to B
setting. (Both are set to A setting in factory shipment.)
The remote control signal is not received when the
settings of indoor unit and remote control are different.
There is no relation between A setting/B setting and A
room/B room when connecting the piping and cables.
<Remote control A-B selection>
To separate using of remote control for each indoor unit
in case of 2 air conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air
conditioner NO.
2. Point the remote control at the indoor unit.
3. Push and hold button on the Remote Control by the
tip of the pencil. "00" will be shown on the display.
4. Press M during pushing . "B" will show on the display
and "00" will disappear and the air conditioner will turn
OFF. The Remote Control B is memorizec.
NOTE : 1. Repeat above step to reset Remote
Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from
factory is A.
B Display
00 Display
OFFON
Check places for
outdoor unit
Check places for
flare nut connection
(Indoor unit)
Valve Cover