Test Run Instructions
You should perform the Test Run for at least 
30 minutes.
1.  Connect power to the unit.
2.  Press the ON/OFF button on the remote 
controller to turn it on.
3.  Press the MODE button to scroll through 
the following functions, one at a time:
 ●  
COOL – Select lowest possible temperature
 ●  
HEAT – Select highest possible temperature
4.  Let each function run for 5 minutes, and 
perform the following checks:
List of Checks to 
Perform
PASS/FAIL
No electrical leakage
Unit is properly 
grounded
All electrical 
terminals properly 
covered
Indoor and outdoor 
units are solidly 
installed
All pipe connection 
points do not leak
Outdoor 
(2):
Indoor 
(2):
Water drains 
properly from drain 
hose
All piping is properly 
insulated
Unit performs COOL 
function properly
Unit performs HEAT 
function properly
Indoor unit louvers 
rotate properly
Indoor unit responds 
to remote controller
DOUBLE-CHECK PIPE CONNECTIONS
During operation, the pressure of the 
refrigerant circuit will increase. This may 
reveal leaks that were not present during 
your initial leak check. Take time during the 
Test Run to double-check that all refrigerant 
pipe connection points do not have leaks. 
Refer to Gas Leak Check section for 
instructions.
5.  After the Test Run is successfully 
completed, and you conrm that all 
checks points in List of Checks to 
Perform have PASSED, do the following:
a.   Using remote control, return unit to 
normal operating temperature.
b.   Using insulation tape, wrap the indoor 
refrigerant pipe connections that you 
left uncovered during the indoor unit 
installation process.
IF AMBIENT TEMPERATURE IS 
BELOW 17°C (62°F)
You can’t use the remote controller to turn 
on the COOL function when the ambient 
temperature is below 17°C. In this instance, 
you can use the MANUAL CONTROL 
button to test the COOL function.
1.  Lift the front panel of the indoor unit, 
and raise it until it clicks in place.
2.  The MANUAL CONTROL button is 
located on the right-hand side of the 
unit. Press it 2 times to select the COOL 
function.
3.  Perform Test Run as normal.