161
Econo Actual Position READ ONLY % dampact AV:211 0 to 1 DAMPACT
Econo Commanded Position R/W % dmpr_cmd AV:4 0 to 1 DAMPCMD
Economizer Damper Starts READ ONLY st_damp AV:139 0 to 999999 ST_DAMP
Economizer Position Test R/W % s_damper AV:118 0 to 1 S_DAMPER
Economizer Travel Time R/W sec eceonotrv AV:226 5 to 300 ECONOTRV
Effective Deadband R/W effdb AV:6007 0 to 55 EFFDB
Effective Demand Temp READ ONLY °F temp_eff AV:163 –40 to 245 TEMP_EFF
Effective Zone Setpoint R/W °F effsp AV:6006 55 to 90 EFFSP
Enthalpy Cross Deadband R/W BTU_LB oa_ra_diff_enth AV:77 0 to 20 OAERAEDB
Equipment Touch RH R/W % EquipmentTouchRH AV:1904 0 to 1 ETSPRH
Equipment Touch SPT R/W °F EquipmentTouchSPT AV:1902 –40 to 240 ETSPT
Fan Supply Air Temp READ ONLY °F idf_sa_temp AV:10 –40 to 245 FST
FBDH Low Set Point R/W °F delta fbdlosp AV:438 –20 to 0 FBDLO_SP
FBDH SAT Min value R/W °F fbdh_sat AV:436 35 to 80 FBDH_SAT
FBDH SAT Set Point READ ONLY °F fbdsatsp AV:441 0 to 240 FBDSATSP
FBDH SST Min value R/W °F fbdh_sst AV:437 10 to 60 FBDH_SST
Filter hour remaining READ ONLY hrs filter_rntm AV:2015 0 to 9999 FILTLEFT
Free Cooling IDF Speed R/W % fspd_free_cool AV:230 0 to 1 FSPD_FCL
Free Cooling Max OAT R/W °F max_free_cl_temp AV:67 0 to 90 MAXFREET
Free Cooling Min Temp R/W °F min_free_cl_temp AV:71 –30 to 70 MINFREET
Free Cooling Reset Count READ ONLY rs_freec AV:104 0 to 65535 RS_FREEC
Free Cooling Run Hours READ ONLY hrs hour_free_cl AV:53 0 to 999999 HR_FREEC
Free Cooling Starts READ ONLY st_freec AV:141 0 to 999999 ST_FREEC
Full Load Resets Count READ ONLY rs_fload AV:103 0 to 65535 RS_FLOAD
Heat Demand Level Up R/W °F hadmd_lup AV:239 –2 to 2 HDMD_LUP
Heat DMD Offset level 1 R/W °F hdlm_level1 AV:403 0 to 40 HTDOLEV1
Heat DMD Offset level 2 R/W °F hdlm_level2 AV:404 0 to 40 HTDOLEV2
Heat DMD Offset level 3 R/W °F hdlm_level3 AV:405 0 to 40 HTDOLEV3
Heat Minimum Off Time R/W sec h_minoff AV:235 60 to 600 H_MINOFF
Heat Minimum On Time R/W sec h_minon AV:236 60 to 600 H_MINON
Heat Mode Select T.guard READ ONLY sec ht_sel_timeguard AV:45 0 to 65535 HEATMSTG
Heat Setpoint in Effect READ ONLY °F hsp_eff AV:243 40 to 80 HSP_EFF
Heat Shed 1 demand band R/W heatsh1 AV:6011 0 to 55 HEATSH1
Heat Shed 2 demand band R/W heatsh2 AV:6012 0 to 55 HEATSH2
Heat Shed 3 demand band R/W heatsh3 AV:6013 0 to 55 HEATSH3
Heat Space Demand Trend READ ONLY htdtrend AV:244 –99 to 99 HTDTREND
Heat Stage 1 Reset Count READ ONLY rs_htr_1 AV:106 0 to 65535 RS_HTR_1
Heat Stage 1 Run Hours READ ONLY hrs hour_ht_1 AV:54 0 to 999999 HR_HTR_1
Heat Stage 1 Starts READ ONLY st_htr_1 AV:142 0 to 999999 ST_HTR_1
Heat Stage 1 Timeguard READ ONLY sec timgd_h1 AV:173 0 to 600 TIMGD_H1
Heat Stage 2 Reset Count READ ONLY rs_htr_2 AV:107 0 to 65535 RS_HTR_2
Heat Stage 2 Run Hours READ ONLY hrs hour_ht_2 AV:55 0 to 999999 HR_HTR_2
Heat Stage 2 Starts READ ONLY st_htr_2 AV:143 0 to 999999 ST_HTR_2
Heat Stage 2 Timeguard READ ONLY sec timgd_h2 AV:50 0 to 600 TIMGD_H2
Heat-Cool Setpoint Gap R/W °F hcsp_gap AV:238 2 to 10 HCSP_GAP
Heating Fan-Off Delay R/W sec heat_fod AV:241 10 to 600 HEAT_FOD
Heating IDF Speed R/W % fspd_heat AV:232 0.2 to 1 FSPD_HT
Heating Lockout Temp R/W °F oatlheat AV:8033 40 to 125 OATLHEAT
Heating Space Demand READ ONLY °F delta heat_dmd AV:240 –100 to 100 HEAT_DMD
High Cool Demand On R/W °F dmdhcon AV:215 0.5 to 20 DMDHCON
High Cooling IDF Speed
R/W % fspd_high_cool AV:231 0.2 to 1 FSPD_HCL
High FreeCool SAT Setpnt R/W °F high_cool_sasp AV:237 40 to 80 HCSASP
High Heat Demand On R/W °F dmdhhon AV:217 0.5 to 20 DMDHHON
HumidiMizer Level Test R/W s_hmzlev AV:414 0 to 2 S_HMZLEV
IAQ Assigned Channel R/W iaq_channel AV:7 0 to 3 IAQ_CHAN
IAQ DCV Curve - Pos 1 READ ONLY % aq_pos1 AV:196 0 to 1 AQ_POS1
IAQ DCV Curve - Pos 2 READ ONLY % aq_pos2 AV:197 0 to 1 AQ_POS2
IAQ DCV Curve - Pos 3 READ ONLY % aq_pos3 AV:198 0 to 1 AQ_POS3
IAQ DCV Curve - Speed 1 READ ONLY % aq_spd1 AV:199 0 to 1 AQ_SPD1
IAQ DCV Curve - Speed 2 READ ONLY % aq_spd2 AV:200 0 to 1 AQ_SPD2
IAQ DCV Curve - Speed 3 READ ONLY % aq_spd3 AV:201 0 to 1 AQ_SPD3
Table Y — BACnet* AV Points List (cont)
POINT DESCRIPTION POINT ACCESS UNITS
BACNET
OBJECT NAME
BACNET
ID
VALUE
RANGE
CCN POINT
EQUIVALENT