54
APPENDIX A — MODEL NUMBER NOMENCLATURE
Fig. A — Model Number Nomenclature
Model Series - WeatherMaker
®
FC 14.0 SEER Standard Efficiency, sizes 04-06
15.2 IEER Standard Efficiency, size 07
Unit Heat Type
50 – Electric Heat Packaged Rooftop
Cooling Tons
04 = 3 tons
05 = 4 tons
06 = 5 tons
07 = 6 tons
Heat Size
- = No heat
Sensor Options
A = None
B = Return Air (RA) Smoke Detector
C = Supply Air (SA) Smoke Detector
D = RA + SA Smoke Detector
E = CO
2
Sensor
F = RA Smoke Detector and CO
2
Sensor
G = SA Smoke Detector and CO
2
Sensor
H = RA + SA Smoke Detector and CO
2
Sensor
J = Condensate Overflow Switch
K = Condensate Overflow Switch and RA Smoke Detector
L = Condensate Overflow Switch and RA and SA Smoke Detectors
M = Condensate Overflow Switch and SA Smoke Detector
Indoor Fan Options
1 = Direct Drive – EcoBlue – Standard Static
2 = Direct Drive – EcoBlue – Medium Static
3 = Direct Drive – EcoBlue – High Static
Refrig. Systems Options
A = Standard One Stage Cooling Models
1
B = Standard One Stage Cooling Models
with Humidi-MiZer
®
system
1, 3
M = Single Circuit, Two Stage Cooling
2
N = Single Circuit, Two Stage Cooling with
Humidi-MiZer system
2, 3
Coil Options – (Outdoor - Indoor - Hail Guard)
A = Al/Cu - Al/Cu
B = Precoat Al/Cu - Al/Cu
C = E-coat Al/Cu - Al/Cu
D = E-coat Al/Cu - E-coat Al/Cu
E = Cu/Cu - Al/Cu
F = Cu/Cu - Cu/Cu
M = Al/Cu - Al/Cu — Louvered Hail Guard
N = Precoat Al/Cu - Al/Cu — Louvered Hail Guard
P = E-coat Al/Cu - Al/Cu — Louvered Hail Guard
Q = E-coat Al/Cu - E-coat Al/Cu — Louvered Hail Guard
R = Cu/Cu - Al/Cu — Louvered Hail Guard
S = Cu/Cu - Cu/Cu — Louvered Hail Guard
Design Revision
- = Factory Design Revision
Base Unit Controls
0 = Electro-mechanical Controls – can be used with
field-installed W7212 EconoMi$er
®
IV
(Non-Fault Detection and Diagnostic)
2 = RTU Open Multi-Protocol Controller
3 = SystemVu
TM
Controls
6 = Electro-mechanical Controls – can be used with W7220
EconoMi$er X (with Fault Detection and Diagnostic)
Intake / Exhaust Options
A = None
B = Temperature Economizer w/ Barometric Relief
F = Enthalpy Economizer w/ Barometric Relief
K = Two-Position Damper
1
U = Temperature Ultra Low Leak Economizer
w/ Barometric Relief
W = Enthalpy Ultra Low Leak Economizer
w/ Barometric Relief
Service Options
0 = None
1 = Unpowered Convenience Outlet
2 = Powered Convenience Outlet
3 = Hinged Panels
4 = Hinged Panels and
Unpowered Convenience Outlet
5 = Hinged Panels and
Powered Convenience Outlet
Packaging & Seismic Compliance
0 = Standard
1 = LTL
Electrical Options
A = None
C = Non-Fused Disconnect
D = Thru-The-Base Connections
F = Non-Fused Disconnect and
Thru-The-Base Connections
Example:
Position:
50FC-A04A2A5-0A0A0
123456789
10
11 12 13 14 15 16 17 18
Voltage
1 = 575/3/60
3 = 208-230/1/60
5 = 208-230/3/60
6 = 460/3/60
1
Size 04/05/06 models only
2
Size 07 models only
3
Units with Humidi-MiZer System include Low Ambient controller
Note: On single phase (-3 voltage code) models, the
following are not available as a factory-installed option:
- Humidi-MiZer System
- Two-Position Damper
- Coated Coils or Cu Fin Coils
- Louvered Hail Guards
- Economizer or 2-Position Damper
- Powered 115 Volt Convenience Outlet

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 50FC A05 Series and is the answer not in the manual?

Carrier 50FC A05 Series Specifications

General IconGeneral
BrandCarrier
Model50FC A05 Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals